基于深度学习的下肢动脉狭窄CT血管造影分类
回顾性纳入265例下肢CTA患者共17050幅轴位图像,以DSA为参考标准训练并验证监督卷积神经网络p-EffNet,按狭窄程度分类膝上及膝下动脉节段。p-EffNet分类膝上动脉准确率91.5%、AUC 0.987,膝下动脉准确率90.9%、AUC 0.981;与放射科医师相比,膝上及膝下动脉准确率和特异度均无显著差异,但敏感度较低。
要点
- p-EffNet分类膝上动脉准确率91.5%、AUC 0.987,膝下动脉准确率90.9%、AUC 0.981。
- 与放射科医师相比,p-EffNet膝上及膝下动脉准确率和特异度无显著差异,敏感度较低。
- p-EffNet有潜力减轻放射科医师工作负荷,并帮助发现可能被遗漏或误判的斑块。
诊断标准与关键数值
- p-EffNet分类膝上动脉:准确率91.5%,AUC 0.987,敏感度90.2%,特异度97.7%。
- p-EffNet分类膝下动脉:准确率90.9%,AUC 0.981,敏感度91.3%,特异度95.2%。
- 与放射科医师比较,膝上动脉准确率p=0.266、特异度p=0.118,膝下动脉准确率p=0.808、特异度p=0.971,均无显著差异。
- 与放射科医师比较,膝上动脉敏感度p<0.001、膝下动脉敏感度p=0.022,p-EffNet敏感度较低。
临床应用与阅片要点
- p-EffNet可用于辅助放射科医师按狭窄程度对下肢动脉CTA节段进行分类,有潜力减轻工作负荷。
- p-EffNet有潜力帮助发现可能被遗漏或误判的斑块。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The purpose of this study is to develop and evaluate a deep learning model to assist radiologists in classifying lower extremity arteries based on the degree of arterial stenosis caused by plaque in lower extremity computed tomography angiography (CTA) of patients with peripheral artery disease.
METHODS: In this retrospective study, 265 patients who underwent lower-extremity CTA between January 1, 2016 and October 31, 2019 were selected. A total of 17050 axial images of iliac, femoropopliteal and infrapopliteal artery from these patients were used for the training and validation of the parallel efficient network (p-EffNet), a kind of supervised convolutional neural network, to classify the lower-extremity artery segments according to the degree of stenosis with digital subtraction angiography as reference standard. The classification results of the p-EffNet were then compared with those obtained from radiologists. Receiver operating characteristic curve (ROC) was used to evaluate the performance of the p-EffNet and accuracy, specificity, sensitivity and area under the curve (AUC) were used as measure metrics to compare the performance of the p-EffNet and that of radiologists.
RESULTS: The p-EffNet exhibited a good performance of 91.5 % accuracy, 0.987 AUC and 90.2 % sensitivity and 97.7 % specificity in classifying above-knee artery and 90.9 % accuracy, 0.981 AUC, 91.3 % sensitivity and 95.2 % specificity in classifying below-knee artery. When compared with human readers, for both above-knee and below-knee artery, the p-EffNet had comparable accuracy (p = 0.266 and p = 0.808, respectively) and specificity (p = 0.118 and p = 0.971, respectively) but lower sensitivity (p < 0.001 and p = 0.022, respectively).
CONCLUSIONS: The p-EffNet demonstrates promising diagnostic performance and has the potential to reduce the workload of radiologists and help to find the plaques that might otherwise have been missed or misjudged.
引用
- Dai L, Zhou Q, Zhou H, et al. Deep learning-based classification of lower extremity arterial stenosis in computed tomography angiography. Eur J Radiol. 2021. PMID: 33450660. doi:10.1016/j.ejrad.2021.109528
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。