文献速递甲状腺与浅表US

比较ACR与Kwak TIRADS应用ACR TIRADS穿刺尺寸阈值后的诊断效能

Comparison of diagnostic performance of the ACR and Kwak TIRADS applying the ACR TIRADS' size thresholds for FNA.
PubMed 文献 · Eur Radiol · 2021-01-15

该回顾性研究纳入2084例患者共2106个≥10 mm甲状腺结节,比较ACR与Kwak两种评分制TIRADS的诊断效能及不必要穿刺率,并将ACR TIRADS的穿刺尺寸阈值套用于Kwak TIRADS形成改良版。改良Kwak TIRADS的特异度、准确率和AUC均高于ACR TIRADS,不必要穿刺率更低,而Kwak TIRADS的假阴性率最低。

要点

  • 改良Kwak TIRADS(套用ACR尺寸阈值)特异度64.7%、准确率70.3%、AUC 0.765,均高于ACR TIRADS。
  • 改良Kwak TIRADS不必要穿刺率54.8%,低于ACR TIRADS的56.4%。
  • Kwak TIRADS假阴性率1.9%,为所有TIRADS中最低。

临床应用与阅片要点

  • 作者结论认为,套用ACR TIRADS尺寸阈值的改良Kwak TIRADS诊断效能更高且不必要穿刺率更低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the diagnostic performances and unnecessary fine-needle aspiration (FNA) rates of two point-scale based TIRADS and compare them with a modified version using the ACR TIRADS' size thresholds.

METHODS: Our Institutional Review Board approved this retrospective study and waived the requirement for informed consent. A total of 2106 thyroid nodules 10 mm or larger in size in 2084 patients with definitive cytopathologic findings were included. Ultrasonography categories were assigned according to each guideline. We applied the ACR TIRADS' size thresholds for FNA to the Kwak TIRADS and defined it as the modified Kwak TIRADS (mKwak TIRADS). Diagnostic performances and unnecessary FNA rates were evaluated for both the original and modified guidelines.

RESULTS: Of the original guidelines, the ACR TIRADS had higher specificity, accuracy, and area under the receiver operating characteristic curve (AUC) (63.1%, 68.9%, and 0.748, respectively). When the size threshold of the ACR TIRADS was applied to the Kwak TIRADS, the resultant mKwak TIRADS had higher specificity, accuracy, and AUC (64.7%, 70.3%, and 0.765, respectively) than the ACR TIRADS. The mKwak TIRADS also had a lower unnecessary FNA rate than the ACR TIRADS (54.8% and 56.4%, respectively). The false-negative rate of the Kwak TIRADS was the lowest (1.9%) among all TIRADS.

CONCLUSION: The modified Kwak TIRADS incorporating the size thresholds of the ACR TIRADS showed higher diagnostic performance and a lower unnecessary FNA rate than the original point-scale based TIRADS.

KEY POINTS: • Of the original guidelines, the ACR TIRADS had the highest specificity, accuracy, and area under the receiver operating characteristic curve (AUC) (63.1%, 68.9%, and 0.748, respectively). • When the size threshold of the ACR TIRADS was applied to the Kwak TIRADS, the resultant modified version of Kwak TIRADS had higher specificity, accuracy, and AUC (64.7%, 70.3%, and 0.765, respectively) than the ACR TIRADS. • The false-negative rate of the Kwak TIRADS was the lowest (1.9%) among all TIRADS.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Huh S, Yoon JH, Lee HS, et al. Comparison of diagnostic performance of the ACR and Kwak TIRADS applying the ACR TIRADS' size thresholds for FNA. Eur Radiol. 2021. PMID: 33449191. doi:10.1007/s00330-020-07591-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。