文献速递头颈神经MR

3T磁共振Dixon-T2WI序列在甲状腺眼病评估中优于常规成像方案

Dixon-T2WI magnetic resonance imaging at 3 tesla outperforms conventional imaging for thyroid eye disease.
PubMed 文献 · Eur Radiol · 2021-01-06

这项前瞻性单中心研究纳入206例确诊甲状腺眼病(TED)患者,在3T MRI上比较单一Dixon-T2WI序列与包括T1WI、T2WI和脂肪抑制T2WI的常规方案的诊断效能。结果显示Dixon-T2WI检测眼外肌炎症的敏感度和特异度更高(100% vs 94.7%;71.2% vs 68.5%),伪影更少,读者信心更高。

要点

  • Dixon-T2WI检测眼外肌炎症的敏感度为100%、特异度为71.2%,均高于常规方案(94.7%、68.5%)。
  • Dixon-T2WI的主要或次要伪影均显著少于脂肪抑制T2WI(5% vs 27%,42% vs 62%)。
  • Dixon-T2WI较常规方案更快,且读者自评信心显著更高(2.35 vs 2.24)。

核心结论

  • 在评估甲状腺眼病时,Dixon-T2WI较常规方案具有更高的敏感度和特异度、更少的伪影以及更高的读者自评信心。

研究设计与样本

  • 经IRB批准的前瞻性单中心研究,2015年4月至2019年10月纳入206例确诊TED的参与者,均接受3T MRI检查(含常规方案和Dixon-T2WI序列),由两名对全部数据设盲的神经放射科医生独立随机阅片,采用Wilcoxon符号秩检验。

关键影像表现/征象

  • Dixon-T2WI检测到至少一条发炎眼外肌的可能性显著高于常规序列组(248/412眼[60%] vs 228/412眼[55%],p=0.02)。
  • Dixon-T2WI的主要伪影显著少于脂肪抑制T2WI(20/412眼[5%] vs 109/412眼[27%],p<0.001)。
  • Dixon-T2WI的次要伪影显著少于脂肪抑制T2WI(175/412眼[42%] vs 257/412眼[62%],p<0.001)。

诊断标准与关键数值

  • Dixon-T2WI评估眼外肌炎症的敏感度为100%、特异度为71.2%,常规方案分别为94.7%和68.5%。
  • Dixon-T2WI的读者自评信心评分为2.35,常规方案为2.24(p=0.003)。

临床应用与阅片要点

  • 原文结论提示,Dixon-T2WI在评估甲状腺眼病眼外肌炎症时敏感度和特异度高于常规方案,且伪影更少。
  • 原文结论提示,Dixon-T2WI较常规方案更快,读者自评信心显著更高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the diagnostic performances of a single Dixon-T2-weighted imaging (WI) sequence compared to a conventional protocol including T1-, T2-, and fat-suppressed T2-weighted MRI at 3 T when assessing thyroid eye disease (TED).

MATERIALS AND METHODS: This IRB-approved prospective single-center study enrolled participants presenting with confirmed TED from April 2015 to October 2019. They underwent an MRI, including a conventional protocol and a Dixon-T2WI sequence. Two neuroradiologists, blinded to all data, read both datasets independently and randomly. They assessed the presence of extraocular muscle (EOM) inflammation, enlargement, fatty degeneration, or fibrosis as well as the presence of artifacts. The Wilcoxon signed-rank test was used.

RESULTS: Two hundred six participants were enrolled (135/206 [66%] women, 71/206 [34%] men, age 52.3 ± 13.2 years). Dixon-T2WI was significantly more likely to detect at least one inflamed EOM as compared to the conventional set (248/412 [60%] versus 228/412 [55%] eyes; (p = 0.02). Dixon-T2WI was more sensitive and specific than the conventional set for assessing muscular inflammation (100% versus 94.7% and 71.2% versus 68.5%, respectively). Dixon-T2WI was significantly less likely to show major or minor artifacts as compared to fat-suppressed T2WI (20/412 [5%] versus 109/412 [27%] eyes, p < 0.001, and 175/412 [42%] versus 257/412 [62%] eyes, p < 0.001). Confidence was significantly higher with Dixon-T2WI than with the conventional set (2.35 versus 2.24, p = 0.003).

CONCLUSION: Dixon-T2WI showed higher sensitivity and specificity and showed fewer artifacts than a conventional protocol when assessing thyroid eye disease, in addition to higher self-reported confidence.

KEY POINTS: • Dixon-T2WI has better sensitivity and specificity than a conventional protocol for assessing inflamed extraocular muscles in patients with thyroid eye disease. • Dixon-T2WI shows significantly fewer artifacts than fat-suppressed T2WI. • Dixon-T2WI is faster and is associated with significantly higher self-reported reader confidence as compared to a conventional protocol when assessing inflammatory extraocular muscles.

来源:Eur Radiol,查看原文。版权归原作者所有。