不同时间点DCE-MRI参数的差异及其对乳腺癌腋窝淋巴结转移的预测价值
回顾性纳入107例乳腺癌患者,于DCE-MRI增强后5个时间点(67.8、128.5、189.2、249.9、310.5秒)提取Ktrans、Kep、Ve、TTP、Peak、Washin、Washout及AUC参数,比较各时间点参数差异并评估其对腋窝淋巴结转移的预测价值。各时间点参数差异有统计学意义(p<0.01),AUC5预测腋窝淋巴结转移的ROC曲线下面积为0.656(p<0.05),可能为独立预测因子。
要点
- DCE-MRI参数在不同增强后时间点取值不同,比较参数时应注明时间点。
- Ktrans与Kep的最优时间点为TP2,Ve为TP4,TTP、Peak及AUC为TP5。
- AUC5预测腋窝淋巴结转移的AUC为0.656(p<0.05),可能为独立预测因子。
核心结论
- DCE-MRI参数值在不同增强后时间点存在差异;AUC5可能为乳腺癌腋窝淋巴结转移的独立预测因子,ROC曲线下面积为0.656(p<0.05)。
研究设计与样本
- 回顾性纳入107例乳腺癌患者,每例采集DCE-MRI 50期图像,于增强后67.8秒、128.5秒、189.2秒、249.9秒、310.5秒(分别记为TP1至TP5)提取Ktrans、Kep、Ve、TTP、Peak、Washin、Washout及AUC参数,采用Wilcoxon符号秩检验比较各时间点参数,Logistic回归分析预测价值并构建ROC曲线。
诊断标准与关键数值
- Ktrans、Kep、Ve的最优时间点分别为TP2、TP2、TP4,TTP、Peak、AUC的最优时间点为TP5;AUC5预测腋窝淋巴结转移的ROC曲线下面积为0.656(p<0.05)。
临床应用与阅片要点
- 阅片及定量分析DCE-MRI参数时需注意参数取值随增强后时间点变化,报告参数时应标注对应时间点;AUC5对腋窝淋巴结转移的预测效能按原文AUC=0.656(p<0.05)表述。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To assess differences of dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) parameters at different postcontrast time points (TPs), and to explore the predictive value of DCE-MRI parameters for axillary lymph node (ALN) metastasis of breast cancer.
MATERIALS AND METHODS: A total of 107 breast cancer patients were included retrospectively, and 50 phases were collected on DCE-MRI for each patient. DCE-MRI parameters Ktrans, Kep, Ve, TTP, Peak, Washin, Washout, and AUC were extracted from the images at 67.8 seconds, 128.5 seconds, 189.2 seconds, 249.9 seconds, and 310.5 seconds (regard as TP1, 2, 3, 4, and 5). Wilcoxon signed rank test was used to compare DCE-MRI parameters at different postcontrast TPs. Logistic regression was performed to analyze the predictive value of DCE-MRI parameters for ALN metastasis of breast cancer, and receiver operating characteristic (ROC) curve was constructed to evaluate the predictive performance.
RESULTS: The difference of DCE-MRI parameters between TP1, 2, 3, 4, and 5 was statistically significant (p < 0.01) in breast cancer. The TPs are considered as the optimal TPs when DCE-MRI parameters values reach the maximum. The optimal TPs of Ktrans, Kep, and Ve were respectively at TP2, TP2, and TP4 (Ktrans2, Kep2, and Ve4). The optimal TPs of TTP, Peak, and AUC were at TP5 (TTP5, Peak5, and AUC5). AUC5 showed the ability to predict ALN metastasis of breast cancer (area under ROC curve = 0.656, p < 0.05).
CONCLUSIONS: DCE-MRI parameters values were different at different postcontrast TPs. AUC5 may be an independent predictor of ALN metastasis in breast cancer.
引用
- Ya G, Wen F, Xing-Ru L, et al. Difference of DCE-MRI Parameters at Different Time Points and Their Predictive Value for Axillary Lymph Node Metastasis of Breast Cancer. Acad Radiol. 2021. PMID: 33504446. doi:10.1016/j.acra.2021.01.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。