文献速递妇产影像US

前置胎盘孕妇胎盘厚度与胎盘植入谱系疾病的相关性

Placental thickness correlates with placenta accreta spectrum (PAS) disorder in women with placenta previa.
PubMed 文献 · Abdom Radiol (NY) · 2021-01-02

本回顾性研究纳入65例前置胎盘孕妇,其中38例经临床或病理证实为胎盘植入谱系疾病(PAS),27例无PAS。PAS组平均胎盘厚度4.3 cm,非PAS组3.0 cm(p < 0.001)。以4.5 cm为阈值,ROC分析显示敏感度50%、特异度96%。

要点

  • 前置胎盘孕妇中,胎盘增厚与胎盘植入谱系疾病(PAS)相关。
  • PAS组平均胎盘厚度4.3 cm,非PAS组3.0 cm(p < 0.001)。
  • 以4.5 cm为阈值,筛查PAS的敏感度50%、特异度96%。

关键影像表现/征象

  • PAS组平均胎盘厚度4.3 cm(范围1.8 cm至7.8 cm),非PAS组3.0 cm(范围0.6 cm至5.3 cm),p < 0.001。
  • 无PAS但有剖宫产史者胎盘厚度3.1(± 1.1)cm,与有剖宫产史且诊断为PAS者4.3 cm相比,P<0.01。

诊断标准与关键数值

  • 以胎盘厚度4.5 cm为阈值,ROC分析得出敏感度50%、特异度96%。

临床应用与阅片要点

  • 对前置胎盘且存在PAS风险因素的患者,可测量胎盘最厚处厚度,4.5 cm阈值可用于筛查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the association of placental thickness with placenta accreta spectrum disorder in placenta previa.

METHODS: In this IRB-approved, retrospective study, ultrasound (US) reports were retrospectively queried for keyword previa. US performed closest to mid-gestation were included. Three measurements were performed at the thickest portion of the placenta on longitudinal transabdominal images. Operative reports and surgical pathology were used as the reference standard. Statistical analysis was performed using unpaired T-tests and receiver operating curve (ROC) analysis.

RESULTS: Sixty-five patients with placenta previa were included: 38 with PAS disorder and 27 without PAS disorder, clinically or pathologically. 38/38 (100%) patients of PAS group and 16/27 (59.3%) patients of non-PAS group had history of prior cesarean section. The average placental thickness was 4.3 cm (range 1.8 cm to 7.8 cm) for PAS group and 3.0 cm (range 0.6 cm to 5.3 cm) for non-PAS group (p < 0.001). Placental thickness in patients without PAS disorder and history of prior cesarean section was 3.1 (± 1.1) cm. This was statistically different from patients who had history of prior cesarean section with PAS diagnosis (4.3 cm, P<0.01). Using ROC analysis, a threshold measurement of 4.5 cm leads to sensitivity of 50% and specificity of 96%.

CONCLUSION: Our results demonstrate that among women with placenta previa, increased placental thickness at lower uterine segment correlates with placenta accreta spectrum disorder. A threshold of 4.5 cm can be useful for screening patients with placenta previa and risks factors for PAS.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Li Y, Choi HH, Goldstein R, et al. Placental thickness correlates with placenta accreta spectrum (PAS) disorder in women with placenta previa. Abdom Radiol (NY). 2021. PMID: 33388802. doi:10.1007/s00261-020-02894-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。