多参数MR评估症状性子宫平滑肌肉瘤及未知恶性潜能软组织肿瘤与平滑肌瘤:拟行高强度聚焦超声治疗者的影像参数准确性及识别恶性的观察者间一致性

Multiparametric MR evaluation of uterine leiomyosarcoma and STUMP versus leiomyoma in symptomatic women planned for high frequency focussed ultrasound: accuracy of imaging parameters and interobserver agreement for identification of malignancy.
PubMed 文献 · Br J Radiol · 2021-01-28

本研究评估多参数MR鉴别子宫平滑肌瘤与平滑肌肉瘤及未知恶性潜能软组织肿瘤的准确性及观察者间一致性。共评估32例平滑肌瘤、10例平滑肌肉瘤和1例未知恶性潜能软组织肿瘤,边缘不规则/不清、T2高信号>50%及周边强化在恶性/交界性病变中更常见。结论认为边缘不规则/不清区分恶性/交界性与平滑肌瘤最佳且观察者间可靠性好。

要点

  • 边缘不规则或不清鉴别平滑肌肉瘤/未知恶性潜能软组织肿瘤与平滑肌瘤最佳,观察者间一致性κ=0.73-0.81。
  • T2高信号>50%及周边强化在平滑肌肉瘤/未知恶性潜能软组织肿瘤中较平滑肌瘤更常见。
  • 弥散受限在平滑肌肉瘤/未知恶性潜能软组织肿瘤中常见,但63-80%平滑肌瘤亦可见。

核心结论

  • 边缘不规则/不清区分平滑肌肉瘤/未知恶性潜能软组织肿瘤与平滑肌瘤最佳,观察者间可靠性好。

研究设计与样本

  • 纳入标准为18岁以上女性,MR上至少一个子宫肿块在三个标准正交方向之一测量≥5 cm,且MR后3个月内病理证实为平滑肌瘤、平滑肌肉瘤或未知恶性潜能软组织肿瘤。
  • 平滑肌肉瘤患者来自评估MR引导聚焦超声适用性的较大队列。
  • 共评估32例平滑肌瘤、10例平滑肌肉瘤和1例未知恶性潜能软组织肿瘤。
  • 评估变量包括病变边缘、边缘清晰度、T2信号均匀性、病变>50%区域T2信号高于子宫肌层、出血、弥散受限、对比增强、强化模式、局部淋巴结肿大和腹水。

关键影像表现/征象

  • 边缘不清(P=0.0003-0.0004)或边缘不规则(P=0.003-0.004)在平滑肌肉瘤/未知恶性潜能软组织肿瘤中较平滑肌瘤更常见,两名放射科医生结果一致。
  • T2高信号>50%(P=0.001-0.004)在平滑肌肉瘤/未知恶性潜能软组织肿瘤中较平滑肌瘤更常见,两名放射科医生结果一致。
  • 周边强化(P=0.02-0.05)在平滑肌肉瘤/未知恶性潜能软组织肿瘤中较平滑肌瘤更常见,两名放射科医生结果一致。
  • 弥散受限见于10/11(阅片者2)和11/11(阅片者1)的平滑肌肉瘤/未知恶性潜能软组织肿瘤,但63-80%的平滑肌瘤也显示弥散受限。
  • 边缘特征的观察者间一致性最高(κ=0.73-0.81)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess accuracy of and interobserver agreement on multiparametric MR findings to distinguish uterine leiomyoma (LM) from uterine leiomyosarcoma (LMS) and soft tissue tumour of unknown malignant potential.

METHODS: Inclusion criteria: All females over 18 years with least one uterine mass measuring 5 cm or more in at least one of the three standard orthogonal dimensions on MR with histopathological confirmation of LM, LMS, or soft tissue tumour of unknown malignant potential (STUMP) in the 3 months following MR. Patients with LMS were drawn from a larger cohort being assessed for MR-guided focussed ultrasound (MRgFUS) suitability. Image evaluation: Assessed variables were: lesion margin, margin definition, T2 signal homogeneity, >50% of lesion with T2 signal brighter than myometrium, haemorrhage, restricted diffusion, contrast enhancement (CE), CE pattern, local lymphadenopathy and ascites.

RESULTS: 32 LM, 10 LMS and 1 STUMP were evaluated. Ill-defined (p-value = 0.0003-0.0004) or irregular (p = 0.003-0.004) lesion margin, T2 hyperintensity >50% (p = 0.001-0.004), and peripheral CE (p = 0.02-0.05) were significantly more common in LMS/STUMP than LM for both radiologists. 10/11 (Reader 2) and 11/11 (Reader 1) LMS/STUMP displayed restricted diffusion but so did 63-80% of LM. Agreement was greatest for margin characteristics (κ = 0.73-0.81).

CONCLUSION: Irregular/ill-defined lesion margin best distinguished LMS/STUMP from LM with good interrater reliability.

ADVANCES IN KNOWLEDGE: Assessment of agreement regarding MR parameters distinguishing LM from LMS and STUMP has not previously been undertaken in a cohort including a large number of patients with LMS. This will help inform evaluation of females considering minimally invasive LM treatment.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Aminzadeh P, Alibrahim E, Dobrotwir A, et al. Multiparametric MR evaluation of uterine leiomyosarcoma and STUMP versus leiomyoma in symptomatic women planned for high frequency focussed ultrasound: accuracy of imaging parameters and interobserver agreement for identification of malignancy. Br J Radiol. 2021. PMID: 33507806. doi:10.1259/bjr.20200483