青春期后患者隐睾及隐睾恶变(精原细胞瘤)的表观扩散系数值
回顾性分析35例单侧阴囊空虚患者的MRI资料,比较正常睾丸、隐睾及隐睾恶变(精原细胞瘤)的平均ADC值。隐睾ADC值高于正常睾丸,精原细胞瘤ADC值低于正常睾丸,差异均有统计学意义(p<0.001)。作者认为隐睾ADC值或可用于辅助临床决策及监测睾丸功能。
要点
- 隐睾平均ADC值(1.82±0.40×10⁻³ mm²/s)高于正常睾丸(1.18±0.18×10⁻³ mm²/s)。
- 隐睾恶变(精原细胞瘤)平均ADC值(0.80±0.06×10⁻³ mm²/s)低于正常睾丸。
- 鉴别正常睾丸与隐睾的ADC阈值1.47×10⁻³ mm²/s,敏感度88%、特异度91%、准确率90%。
核心结论
- 隐睾的ADC值可能用于辅助临床决策,并可用于监测保留未降睾丸或术后患者的睾丸功能。
研究设计与样本
- 回顾性分析35例单侧阴囊空虚患者的病历资料。
- 分为三组:A组正常睾丸(隐睾或隐睾恶变患者的对侧睾丸)、B组隐睾、C组隐睾恶变(精原细胞瘤)。
- DWI采用b值0和800 s/mm²,比较平均ADC值并采用受试者工作特征曲线分析。
关键影像表现/征象
- 正常睾丸平均ADC值为1.18±0.18×10⁻³ mm²/s,隐睾为1.82±0.40×10⁻³ mm²/s,隐睾恶变为0.80±0.06×10⁻³ mm²/s。
- 正常睾丸与隐睾或隐睾恶变之间的平均ADC值差异有统计学意义(p<0.001)。
诊断标准与关键数值
- 鉴别正常睾丸与隐睾的ADC阈值为1.47×10⁻³ mm²/s,敏感度88%、特异度91%、准确率90%。
- 鉴别正常睾丸与隐睾恶变的ADC阈值为1.22×10⁻³ mm²/s,敏感度100%、特异度31%、准确率43%。
临床应用与阅片要点
- 测量睾丸ADC值时,隐睾ADC值高于正常睾丸,而隐睾恶变(精原细胞瘤)ADC值低于正常睾丸。
- 作者认为隐睾ADC值可能用于辅助临床决策及监测保留未降睾丸或术后患者的睾丸功能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Diffusion-weighted imaging signal contrast can be quantified by apparent diffusion coefficient (ADC) maps, which reflect the diffusion properties of the examined tissue and are helpful for identifying pathology. To determine ADC values of cryptorchid testes in post-pubertal patients and assess performance for characterizing cryptorchid testes.
METHODS: The medical records from 35 patients with unilateral scrotal vacuity were retrospectively reviewed. Data were analyzed in three groups: Group A, normal testes (i.e. the contralateral testes of the patients with cryptorchidism or MTC); Group B, cryptorchid testes; and Group C, malignant transformation of cryptorchidism (MTC) (seminoma). DWI used b-values of 0 and 800 s/mm2. Mean ADC values were compared using the independent samples t-test. The ability of ADC values was assessed using receiver operating characteristic curve analysis. The sensitivity, specificity, and accuracy were calculated.
RESULTS: Mean ADC values for normal testes, cryptorchid testes, and MTC were 1.18 ± 0.18×10-3 mm2/s, 1.82 ± 0.40×10-3 mm2/s, and 0.80 ± 0.06×10-3 mm2/s, respectively. There were statistically significant differences in mean ADC values between normal testes and cryptorchid testes or MTC (p < 0.001). The cut-off ADC value for differentiating normal testes from cryptorchid testes was 1.47 × 10-3 mm2/s. The sensitivity, specificity, and accuracy were 88%, 91%, and 90%, respectively. The cut-off ADC value for differentiating normal testes from MTC was 1.22 × 10-3 mm2/s. The sensitivity, specificity, and accuracy were 100%, 31%, and 43%, respectively.
CONCLUSION: ADC values of cryptorchid testes may be used to inform clinical decision-making and also monitor testicular function in patients who retain undescended testicles or post-operatively.
ADVANCES IN KNOWLEDGE: Mean ADC values of cryptorchidism and MTC (seminoma) were used to reflect their pathological features.
引用
- Liu R, Li J, Jiang Y, et al. Apparent diffusion coefficient values of cryptorchid testes and malignant transformation of cryptorchidism (MTC) (seminoma) in postpubertal patients. Br J Radiol. 2021. PMID: 33411594. doi:10.1259/bjr.20200624
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。