双参数MRI与68Ga-PSMA-PET在前列腺癌GTV勾画中的比较:专家轮廓与半自动方法的对比
本研究纳入16例未治疗前列腺癌患者,由4名观察者在双参数MRI、68Ga-PSMA-PET/CT及融合图像上手动勾画优势前列腺内病灶,并与基于ADC和SUV定量阈值的半自动分割比较。结果显示PSMA-PET的观察者间一致性高于双参数MRI,半自动分割与共识GTV的一致性在PSMA-PET上更高但总体仍低。
要点
- PSMA-PET勾画的观察者间一致性高于双参数MRI(DSC 0.822 vs 0.705)。
- 双参数MRI与PSMA-PET勾画之间的模态间一致性低(DSC 0.440)。
- 半自动分割与共识GTV一致性在MRI低(DSC 0.370)、PSMA-PET较高(DSC 0.571)。
诊断标准与关键数值
- 观察者间一致性:GTVPSMA的DSC为0.822、MDA为1.12 mm;GTVFused的DSC为0.787、MDA为1.34 mm;GTVMRI的DSC为0.705、MDA为2.44 mm,GTVPSMA和GTVFused显著高于GTVMRI(p < 0.05)。
- 模态间一致性:GTVMRI与GTVPSMA之间DSC为0.440、MDA为4.64 mm。
- 半自动分割与共识GTV一致性:MRI的DSC为0.370、MDA为8.16 mm;PSMA-PET的DSC为0.571、MDA为4.45 mm,PSMA-PET显著高于MRI(p < 0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The optimal method for delineation of dominant intraprostatic lesions (DIL) for targeted radiotherapy dose escalation is unclear. This study evaluated interobserver and intermodality variability of delineations on biparametric MRI (bpMRI), consisting of T2 weighted (T2W) and diffusion-weighted (DWI) sequences, and 68Ga-PSMA-PET/CT; and compared manually delineated GTV contours with semi-automated segmentations based on quantitative thresholding of intraprostatic apparent diffusion coefficient (ADC) and standardised uptake values (SUV).
METHODS: 16 patients who had bpMRI and PSMA-PET scanning performed prior to any treatment were eligible for inclusion. Four observers (two radiation oncologists, two radiologists) manually delineated the DIL on: (1) bpMRI (GTVMRI), (2) PSMA-PET (GTVPSMA) and (3) co-registered bpMRI/PSMA-PET (GTVFused) in separate sittings. Interobserver, intermodality and semi-automated comparisons were evaluated against consensus Simultaneous Truth and Performance Level Estimation (STAPLE) volumes, created from the relevant manual delineations of all observers with equal weighting. Comparisons included the Dice Similarity Coefficient (DSC), mean distance to agreement (MDA) and other metrics.
RESULTS: Interobserver agreement was significantly higher (p < 0.05) for GTVPSMA (DSC: 0.822, MDA: 1.12 mm) and GTVFused (DSC: 0.787, MDA: 1.34 mm) than for GTVMRI (DSC: 0.705, MDA 2.44 mm). Intermodality agreement between GTVMRI and GTVPSMA was low (DSC: 0.440, MDA: 4.64 mm). Agreement between semi-automated volumes and consensus GTV was low for MRI (DSC: 0.370, MDA: 8.16 mm) and significantly higher for PSMA-PET (0.571, MDA: 4.45 mm, p < 0.05).
CONCLUSION: 68Ga-PSMA-PET appears to improve interobserver consistency of DIL localisation vs bpMRI and may be more viable for simple quantitative delineation approaches; however, more sophisticated approaches to semi-automatic delineation factoring for patient- and disease-related heterogeneity are likely required.
ADVANCES IN KNOWLEDGE: This is the first study to evaluate the interobserver variability of prostate GTV delineations with co-registered bpMRI and 68Ga-PSMA-PET.
引用
- Hearn N, Blazak J, Vivian P, et al. Prostate cancer GTV delineation with biparametric MRI and 68Ga-PSMA-PET: comparison of expert contours and semi-automated methods. Br J Radiol. 2021. PMID: 33507812. doi:10.1259/bjr.20201174
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。