文献速递腹部泌尿生殖技术与安全CT

多材料分解算法虚拟平扫双能CT图像:对肾脏肿块和尿路结石评估的诊断价值

Virtual Unenhanced Dual-Energy CT Images Obtained with a Multimaterial Decomposition Algorithm: Diagnostic Value for Renal Mass and Urinary Stone Evaluation.
PubMed 文献 · Radiology · 2021-01-19

该回顾性研究纳入221例患者273个肾脏肿块和166枚尿路结石,比较虚拟平扫与真实平扫图像。虚拟平扫对肾脏肿块强化与非强化囊肿分类的重分类率为0%,但对尿路结石诊断的AUC低于真实平扫(0.79 vs 0.93,P < .001),主要因≤3 mm结石敏感度降低。

要点

  • 虚拟平扫与真实平扫测量的肾脏肿块CT值差异在3 HU以内,强化肿块和非强化囊肿的95%一致性界限分别为-3.1至2.7 HU和-2.9至2.5 HU。
  • 以虚拟平扫替代真实平扫,强化肿块和非强化囊肿的分类重分类率均为0%(0/78和0/193)。
  • 虚拟平扫对尿路结石诊断的AUC为0.79,低于真实平扫的0.93(P < .001),≤3 mm结石敏感度仅23%。

关键影像表现/征象

  • 虚拟平扫与真实平扫测量的肾脏肿块CT值差异在3 HU以内:强化肿块95%一致性界限为-3.1至2.7 HU,非强化囊肿为-2.9至2.5 HU。
  • 以虚拟平扫替代真实平扫,强化肿块重分类率为0%(0/78;95% CI:0,5),非强化囊肿重分类率为0%(0/193;95% CI:0,2)。

诊断标准与关键数值

  • 虚拟平扫对尿路结石诊断的AUC为0.79(95% CI:0.73,0.84),低于真实平扫的0.93(95% CI:0.91,0.95),P < .001。
  • 虚拟平扫对直径≤3 mm结石的敏感度为23%(25/108;95% CI:12,40),对直径>3 mm结石的敏感度为88%(126/144;95% CI:77,94),P < .001。

临床应用与阅片要点

  • 虚拟平扫可用于肾脏肿块强化与非强化囊肿的分类评估,与真实平扫相比重分类率为0%。
  • 虚拟平扫对尿路结石检测的敏感度较低,尤其对直径≤3 mm结石敏感度仅23%,阅片时需注意此局限性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Virtual unenhanced (VUE) images obtained by using a dual-energy CT (DECT) multimaterial decomposition algorithm hold promise for diagnostic use in the abdomen in lieu of true unenhanced (TUE) images. Purpose To assess VUE images obtained from a DECT multimaterial decomposition algorithm in patients undergoing renal mass and urinary stone evaluation. Materials and Methods In this retrospective Health Insurance Portability and Accountability Act-compliant study, DECT was performed in patients undergoing evaluation for renal mass or urinary stone. VUE images were compared quantitatively to TUE images and qualitatively assessed by four independent radiologists. Differences in attenuation between VUE and TUE images were summarized by using 95% limits of agreement. Diagnostic performance in urinary stone detection was summarized by using area under the receiver operating characteristic curve, sensitivity, and specificity. Results A total of 221 patients (mean age ± standard deviation, 61 years ± 14; 129 men) with 273 renal masses were evaluated. Differences in renal mass attenuation between VUE and TUE images were within 3 HU for both enhancing masses (95% limits of agreement, -3.1 HU to 2.7 HU) and nonenhancing cysts (95% limits of agreement, -2.9 HU to 2.5 HU). Renal mass classification as enhancing mass versus nonenhancing cyst did not change (reclassification rate of enhancing masses, 0% [0 of 78]; 95% CI: 0, 5; reclassification rate of nonenhancing cysts, 0% [0 of 193]; 95% CI: 0, 2) with use of VUE in lieu of TUE images. Among 166 urinary stones evaluated, diagnostic performance of VUE images for stone detection was lower compared with that of TUE images (area under the receiver operating characteristic curve, 0.79 [95% CI: 0.73, 0.84] vs 0.93 [95% CI: 0.91, 0.95]; P < .001) due to reduced sensitivity of VUE for detection of stones 3 mm in diameter or less compared with those greater than 3 mm (sensitivity, 23% [25 of 108; 95% CI: 12, 40] vs 88% [126 of 144; 95% CI: 77, 94]; P < .001). Conclusion Compared with true unenhanced images, virtual unenhanced (VUE) images were unlikely to change renal mass classification as enhancing mass versus nonenhancing cyst. Diagnostic performance of VUE images remained suboptimal for urinary stone detection due to subtraction of stones 3 mm or less in diameter. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Sosna in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Xiao JM, Hippe DS, Zecevic M, et al. Virtual Unenhanced Dual-Energy CT Images Obtained with a Multimaterial Decomposition Algorithm: Diagnostic Value for Renal Mass and Urinary Stone Evaluation. Radiology. 2021. PMID: 33464180. doi:10.1148/radiol.2021192448

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。