文献速递腹部泌尿生殖技术与安全CT

基于三维U-Net深度卷积神经网络的CT尿路造影肾脏与肾肿块自动分割及肾肿块自动检测

Automated segmentation of kidney and renal mass and automated detection of renal mass in CT urography using 3D U-Net-based deep convolutional neural network.
PubMed 文献 · Eur Radiol · 2021-01-13

研究采用基于三维U-Net的深度学习模型,对441例肾肿块患者CT尿路造影皮质髓质期图像的882个肾脏进行肾脏和肾肿块自动分割及检测,另用35例小肾肿瘤(直径≤1.5 cm)数据追加测试。模型分割肾脏和肾肿瘤平均DSC分别为0.973和0.844,肾囊肿分割平均DSC为0.536,检测肾肿瘤和囊肿表现良好。作者认为该模型在肾脏和肾肿瘤分割及肾肿瘤、囊肿检测方面结果有前景。

要点

  • 模型对肾脏和肾肿瘤分割平均DSC分别为0.973和0.844,肾囊肿分割平均DSC仅0.536。
  • 以预测分割中肾肿瘤和囊肿最大三维感兴趣区体积作为识别指标,检测肾肿瘤和囊肿表现良好。
  • 作者认为该全自动辅助诊断工具可能减少放射科医生工作量并提高诊断准确性。

核心结论

  • 基于三维U-Net的自动分割与检测模型在CT尿路造影皮质髓质期对肾脏和肾肿瘤分割及肾肿瘤、囊肿检测方面显示出有前景的结果。

研究设计与样本

  • 研究使用441例肾肿块患者CT尿路造影数据共882个肾脏学习和评估深度学习模型,另用35例小肾肿瘤(直径≤1.5 cm)患者CTU数据进行追加测试。
  • 肾脏、肾肿瘤和囊肿的参考标准在CTU皮质髓质期图像上手动标注,分割模型基于三维U-Net构建,分割精度以Dice相似系数(DSC)评估。
  • 以模型预测分割中肾肿瘤和囊肿最大三维感兴趣区体积作为识别指标,检测性能以受试者工作特征曲线下面积评估。

诊断标准与关键数值

  • 肾脏分割平均DSC为0.973,肾肿瘤分割平均DSC为0.844。
  • 测试集肾囊肿分割平均DSC为0.536。
  • 检测肾肿瘤和囊肿表现良好,原文未报告具体AUC数值。

临床应用与阅片要点

  • 作者认为该基于三维U-Net的分割模型是全自动辅助诊断工具,可能减少放射科医生工作量并提高诊断准确性。
  • 作者认为该模型可能有助于为诊断、治疗、手术规划等提供定量信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To develop a 3D U-Net-based deep learning model for automated segmentation of kidney and renal mass, and detection of renal mass in corticomedullary phase of computed tomography urography (CTU).

METHODS: Data on 882 kidneys obtained from CTU data of 441 patients with renal mass were used to learn and evaluate the deep learning model. The CTU data of 35 patients with small renal tumors (diameter ≤ 1.5 cm) were used for additional testing. The ground truth data for the kidney, renal tumor, and cyst were manually annotated on corticomedullary phase images of CTU. The proposed segmentation model for kidney and renal mass was constructed based on a 3D U-Net. The segmentation accuracy was evaluated through the Dice similarity coefficient (DSC). The volume of the maximum 3D volume of interest of renal tumor and cyst in the predicted segmentation by the model was used as an identification indicator, while the detection performance of the model was evaluated by the area under the receiver operation characteristic curve.

RESULTS: The proposed model showed a high accuracy in segmentation of kidney and renal tumor, with average DSC of 0.973 and 0.844, respectively. It performed moderately in the renal cyst segmentation, with an average DSC of 0.536 in the test set. Also, this model showed good performance in detecting renal tumor and cyst.

CONCLUSIONS: The proposed automated segmentation and detection model based on 3D U-Net shows promising results for the segmentation of kidney and renal tumor, and the detection of renal tumor and cyst.

KEY POINTS: • The segmentation model based on 3D U-Net showed high accuracy in segmentation of kidney and renal neoplasm, and good detection performance of renal neoplasm and cyst in corticomedullary phase of CTU. • The segmentation model based on 3D U-Net is a fully automated aided diagnostic tool that could be used to reduce the workload of radiologists and improve the accuracy of diagnosis. • The segmentation model based on 3D U-Net would be helpful to provide quantitative information for diagnosis, treatment, surgical planning, etc.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lin Z, Cui Y, Liu J, et al. Automated segmentation of kidney and renal mass and automated detection of renal mass in CT urography using 3D U-Net-based deep convolutional neural network. Eur Radiol. 2021. PMID: 33439313. doi:10.1007/s00330-020-07608-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。