单期门静脉期双能CT生成模拟双期胰腺协议CT在胰腺导管腺癌中的应用
本研究回顾性纳入63例胰腺导管腺癌患者,基于单次门静脉期双能CT采集生成模拟双期胰腺协议CT(40 keV/65 keV门静脉期),与标准双期协议(50 keV胰腺期/65 keV门静脉期)比较。结果显示两种方案对PDAC检出率无显著差异(标准方案58/63,92.1%;模拟方案56/63,88.9%,P=0.76),图像质量、胰腺信噪比及对比噪声比相当,模拟方案辐射剂量较标准方案降低44%。
要点
- 单次门静脉期双能CT可生成模拟双期胰腺协议CT,PDAC检出率与标准双期协议无显著差异。
- 模拟方案在腹腔干、肠系膜上、脾、肝总、胃十二指肠、第一空肠动脉及主动脉受侵评分上与标准方案相当。
- 模拟方案平均剂量长度乘积较标准方案降低44%,可能有利于胰腺疾病监测和筛查。
关键影像表现/征象
- 标准协议与模拟协议对PDAC的检出率分别为58/63(92.1%)和56/63(88.9%),差异无统计学意义(P=0.76)。
- 腹腔干(P=0.86)、肠系膜上(P=0.88)、脾(P=0.86)、肝总(P=0.52)、胃十二指肠(P=0.95)、第一空肠(P=0.48)动脉及主动脉(P=1.00)受侵的主观评分在两种协议间相当。
- 图像质量(P=0.14)、胰腺信噪比(P=0.15)和对比噪声比(P=0.54)在两种协议间相当。
临床应用与阅片要点
- 模拟协议的平均剂量长度乘积为629.6 ± 148.3 mGy cm,标准协议为1123.3 ± 268.9 mGy cm,模拟协议辐射剂量降低44%(P<0.0001)。
- 作者认为辐射剂量降低在胰腺疾病监测和筛查中是可取的。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic performance of a simulated twin-phase pancreatic protocol CT generated from a single portal venous phase (PVP) dual-energy CT (DECT) acquisition in patients with pancreatic ductal adenocarcinoma (PDAC).
METHODS: In this retrospective study, we included 63 patients with PDAC who underwent pancreatic protocol (pancreatic phase [PP] and PVP) DECT. Two data sets were created from this original acquisition-(1) Standard protocol (50 keV PP/65 keV PVP) and (2) Simulated protocol (40 keV/65 keV PVP). Using a 5-point scale, three readers scored image quality, tumor conspicuity, and arterial involvement by the PDAC. Signal-to-noise ratio (SNR) of the pancreas and tumor-to-pancreas contrast-to-noise ratio (CNR) were calculated. Qualitative scores, quantitative parameters, and radiation dose were compared between standard and simulated protocols.
RESULTS: No significant difference in detection rate of PDAC was seen between the standard (58/63, 92.1%) and simulated protocols (56/63, 88.9%) (P = 0.76). Subjective scoring for arterial involvement for celiac (P = 0.86), superior mesenteric (P = 0.88), splenic (P = 0.86), common hepatic (P = 0.52), gastroduodenal (P = 0.95), first jejunal (P = 0.48) arteries, and aorta (P = 1.00) were comparable between two protocols. The image quality (P = 0.14), the SNR of the pancreas (P = 0.15), and CNR (P = 0.54) were comparable between two protocols. The projected mean dose-length product (DLP) (629.6 ± 148.3 mGy cm) in the simulated protocol showed a 44% reduction in radiation dose compared to the standard protocol (mean DLP, 1123.3 ± 268.9 mGy cm) (P < 0.0001).
CONCLUSIONS: Low keV images generated from a PVP DECT acquisition allows creation of a twin-phase pancreatic protocol CT with comparable diagnostic accuracy for detecting PDAC with significant reduction in radiation dose. Reduced radiation dose is desirable in surveillance and screening for pancreatic diseases.
引用
- Noda Y, Tochigi T, Parakh A, et al. Simulated twin-phase pancreatic CT generated using single portal venous phase dual-energy CT acquisition in pancreatic ductal adenocarcinoma. Abdom Radiol (NY). 2021. PMID: 33454806. doi:10.1007/s00261-020-02921-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。