文献速递腹部技术与安全MRUS

无创评估肝纤维化:拉伸指数扩散加权模型与其他扩散加权MRI模型及瞬时弹性成像的比较

Noninvasive evaluation of liver fibrosis: comparison of the stretched exponential diffusion-weighted model to other diffusion-weighted MRI models and transient elastography.
PubMed 文献 · Eur Radiol · 2021-01-13

这项回顾性研究纳入78例同时接受DWI和瞬时弹性成像(TE)的连续患者,比较拉伸指数模型与其他DWI模型及TE对肝纤维化分期的诊断效能。拉伸指数模型的分布扩散系数(DDC)是唯一能区分F0-1与F2-3(p<0.001)以及F2-3与F4(p=0.013)的参数,其诊断效能最高(0.717;95%CI 0.653-0.765),与TE(0.681;95%CI 0.623-0.733)无显著差异(p>0.999)。DDC与纤维化和炎症显著相关,但与脂肪变性无关,多回归分析中仅与纤维化独立相关。

要点

  • DDC是唯一能区分F0-1与F2-3(p<0.001)及F2-3与F4(p=0.013)的DWI参数。
  • DDC诊断肝纤维化效能最高(0.717;95%CI 0.653-0.765),与TE(0.681;95%CI 0.623-0.733)无显著差异(p>0.999)。
  • DDC与脂肪变性无关(p=0.619),而ADC、Dp、Dt与脂肪变性显著相关(ps≤0.038)。

核心结论

  • 拉伸指数模型的DDC是诊断肝纤维化最准确的DWI参数,不受脂肪变性混杂影响,整体诊断效能与TE相似。

研究设计与样本

  • 回顾性研究纳入78例连续患者,均接受DWI和瞬时弹性成像(TE)检查。
  • 获取拉伸指数模型的分布扩散系数(DDC)和体素内异质性指数(α),以及ADC、灌注分数(f)、伪扩散系数(Dp)、真实扩散系数(Dt)和TE。
  • 采用Spearman相关和多回归分析评估影像参数与病理纤维化、炎症和脂肪变性的关联,通过Obuchowski measures评估诊断准确性。

诊断标准与关键数值

  • DDC用于区分F0-1与F2-3的p<0.001,区分F2-3与F4的p=0.013。
  • DDC与纤维化(p<0.001)和炎症(p=0.001)显著相关,与脂肪变性无显著相关(p=0.619)。
  • 多回归分析中DDC仅与纤维化独立相关(β=-0.114,p<0.001)。
  • ADC、Dp和Dt与脂肪变性显著相关(ps≤0.038)。
  • DDC诊断肝纤维化的Obuchowski measure为0.717(95%CI 0.653-0.765),TE为0.681(95%CI 0.623-0.733),两者无显著差异(p>0.999)。

临床应用与阅片要点

  • 拉伸指数模型的DDC可作为评估肝纤维化的DWI参数,其诊断效能与TE相似且不受脂肪变性影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the diagnostic performance of the stretched exponential model to those of other DWI models and transient elastography (TE) and to evaluate the influence of confounding factors on the staging of liver fibrosis.

METHODS: This retrospective study included 78 consecutive patients who underwent both DWI and TE. The distributed diffusion coefficient (DDC) and intravoxel heterogeneity index (α) from the stretched exponential model, apparent diffusion coefficient (ADC), perfusion fraction (f), pseudodiffusion coefficient (Dp), true diffusion coefficient (Dt), and TE were obtained. Associations between imaging parameters and pathological fibrosis, inflammation, and steatosis were evaluated using Spearman's correlation and multiple regression analysis. Diagnostic accuracy of parameters for fibrosis staging was assessed via the Obuchowski measures.

RESULTS: DDC was the only parameter to differ between F0-1 and F2-3 (p < 0.001) and between F2-3 and F4 (p = 0.013). DDC showed significant correlation with fibrosis (p < 0.001) and inflammation (p = 0.001), but not with steatosis (p = 0.619), and was independently associated with only fibrosis in multiple regression analysis (β = - 0.114, p < 0.001). ADC, Dp, and Dt showed a significant correlation with steatosis (ps ≤ 0.038). DDC showed the highest diagnostic performance for liver fibrosis (0.717; 95% confidence interval, 0.653-0.765) followed by TE (0.681, 0.623-0.733) without a significant difference between DDC and TE (p > 0.999).

CONCLUSIONS: DDC from the stretched exponential model is the most accurate DWI parameter with no confounding effect from steatosis and with overall similar diagnostic performance to TE.

KEY POINTS: • The distributed diffusion coefficient (DDC) from the stretched exponential model is the most accurate DWI parameter for staging liver fibrosis. • DDC and transient elastography have similar good diagnostic performance for evaluating liver fibrosis. • The stretched exponential DWI model has no confounding effect by steatosis, unlike other DWI models.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Park JH, Seo N, Chung YE, et al. Noninvasive evaluation of liver fibrosis: comparison of the stretched exponential diffusion-weighted model to other diffusion-weighted MRI models and transient elastography. Eur Radiol. 2021. PMID: 33439321. doi:10.1007/s00330-020-07600-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。