二维剪切波弹性成像在预测肝切除术后并发症方面优于瞬时弹性成像
该前瞻性研究纳入125例肝肿瘤患者,术前用瞬时弹性成像(TE)和二维剪切波弹性成像(2D-SWE)测量肝硬度,评估其对肝切除术后严重并发症(综合并发症指数CCI≥26.2)的预测价值。结果显示2D-SWE测得的肝硬度是严重并发症的显著预测因子(每kPa OR 1.27),且2D-SWE预测严重并发症的AUC为0.854,显著高于TE的0.692(p=0.004)。
要点
- 2D-SWE预测肝切除术后严重并发症的AUC为0.854,显著高于TE的0.692(p=0.004)。
- 2D-SWE预测严重并发症的最佳截断值为8.6 kPa,敏感度88.9%、特异度73.8%。
诊断标准与关键数值
- 2D-SWE预测严重并发症的AUC为0.854,显著高于TE的AUC 0.692(p=0.004)。
- 2D-SWE预测严重并发症的最佳截断值为8.6 kPa,敏感度88.9%(16/18),特异度73.8%(79/107)。
- 2D-SWE检测≥F3的AUC为0.853,显著高于TE的0.779(p=0.024)。
- 2D-SWE检测F4的AUC为0.929,显著高于TE的0.872(p=0.048)。
临床应用与阅片要点
- 原文结论提示2D-SWE测得的肝硬度是严重并发症的显著预测因子,且诊断性能优于TE,但未给出具体临床操作建议。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Both transient elastography (TE) and 2D shear wave elastography (SWE) are accurate methods to evaluate liver fibrosis. We aimed to evaluate the diagnostic performance of 2D-SWE in predicting post-hepatectomy complication and to compare it with TE.
METHODS: We prospectively enrolled 125 patients with liver tumors. Liver stiffness (LS) (kilopascal [kPa]) was measured using both TE and 2D-SWE before surgery. All post-operative complication was evaluated using the comprehensive complication index (CCI), and CCI ≥ 26.2 was defined as severe complication. Logistic regression analysis was performed to identify predictive factors for severe complication. Receiver operating characteristic analysis was used to evaluate the diagnostic performance of TE/2D-SWE in detecting liver fibrosis and severe complication.
RESULTS: Severe complication developed in 18 patients. The median LS in patients with severe complication was significantly higher for both 2D-SWE (11.4 kPa vs. 7.0 kPa, p < 0.001) and TE (8.9 kPa vs. 6.2 kPa, p = 0.009). LS obtained from 2D-SWE was a significant factor correlated with severe complication (odds ratio: 1.27 per kPa [1.10-1.46], p = 0.001). The diagnostic performance of 2D-SWE was significantly higher than that of TE in detecting both ≥F3 (p = 0.024) and F4 (p = 0.048). The area under the curve of 2D-SWE to predict severe complication was 0.854, significantly higher than 0.692 of TE (p = 0.004). The optimal cut-off LS from 2D-SWE to predict severe complication was 8.6 kPa, with sensitivity of 88.9% (16/18) and specificity of 73.8% (79/107).
CONCLUSION: LS obtained from 2D-SWE was a significant predictive factor for severe complication, and 2D-SWE showed significantly a better diagnostic performance than TE in detecting liver fibrosis and severe complication.
KEY POINTS: • The diagnostic performance of 2D-SWE was significantly higher than that of TE in detecting both ≥ F3 (AUC: 0.853 vs. 0.779, p = 0.024) and F4 (AUC: 0.929 vs. 0.872, p = 0.048). • Liver stiffness value obtained from 2D-SWE was a significant factor correlated with the development of severe complication defined as CCI ≥ 26.2 after hepatic resection for liver tumors (odds ratio: 1.27 per kPa [1.10-1.46], p = 0.001). • 2D-SWE provided significantly a better diagnostic performance in predicting severe complication after hepatic resection than TE (AUC for 2D-SWE: 0.853 vs. AUC for TE: 0.692, p = 0.004).
引用
- Lee DH, Lee ES, Bae JS, et al. 2D shear wave elastography is better than transient elastography in predicting post-hepatectomy complication after resection. Eur Radiol. 2021. PMID: 33459859. doi:10.1007/s00330-020-07662-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。