文献速递腹部技术与安全US

结直肠癌肝转移灶的剪切波速度可作为化疗后潜在预后因素:一项初步研究

Shear-wave velocity for colorectal cancer liver metastases as a potential prognostic factor after chemotherapy: a preliminary study.
PubMed 文献 · Clin Radiol · 2021-01-02

前瞻性研究纳入25例结直肠癌肝转移患者,用点剪切波弹性成像于化疗前及化疗后2、7、14天测剪切波速度(SWV),另纳入37例评估测量可重复性。化疗后第2天SWV较基线下降是无进展生存期(PFS)更好的显著预测因素(HR=0.20,95%CI 0.07–0.57,P=0.003),SWV组内相关系数(ICC)为0.823(95%CI 0.685–0.905)。

要点

  • 化疗后第2天SWV较基线下降者PFS更好,HR=0.20(95%CI 0.07–0.57,P=0.003)。
  • 第2天SWV下降的9例1年、3年PFS分别为66.7%、22.2%,高于SWV升高16例的18.8%、0%。
  • 肝转移灶SWV测量ICC为0.823(95%CI 0.685–0.905),一致性良好。

核心结论

  • 结直肠癌肝转移灶的SWV值可提供化疗患者的预后信息,化疗后第2天SWV下降是PFS更好的显著预测因素。

研究设计与样本

  • 前瞻性研究,经本院机构审查委员会批准并取得书面知情同意。
  • 预后分析纳入25例结直肠癌肝转移患者,采用声辐射力脉冲的点剪切波弹性成像于化疗前及化疗后2、7、14天测量SWV。
  • 另纳入37例结直肠癌肝转移患者,用组内相关系数(ICC)评估SWV测量的可重复性。
  • 采用Kaplan-Meier法估计化疗后PFS,采用Cox比例风险回归模型确定PFS的显著预测因素。

诊断标准与关键数值

  • 化疗后第2天SWV值较初始值下降是PFS更好的显著预测因素,HR=0.20(95%CI 0.07–0.57,P=0.003)。
  • 全队列估计1年、3年PFS分别为36%和8%。
  • 第2天SWV下降的9例估计1年、3年PFS分别为66.7%、22.2%,显著高于第2天SWV升高的16例的18.8%和0%。
  • 追加37例结直肠癌肝转移患者SWV的ICC为0.823(95%CI 0.685–0.905),提示一致性良好。

临床应用与阅片要点

  • 对结直肠癌肝转移化疗患者,可于化疗前及化疗后第2天用点剪切波弹性成像测量SWV,观察其较基线的变化方向。
  • 解读SWV变化时需结合测量可重复性,本研究中肝转移灶SWV的ICC为0.823(95%CI 0.685–0.905)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate whether shear-wave velocity (SWV) can be used for predicting the prognoses of patients with colorectal cancer liver metastases (CRLMs) after chemotherapy.

MATERIALS AND METHODS: Our institutional review board approved this prospective study, and written informed consent was obtained. SWV of CRLMs were obtained using point shear-wave elastography using acoustic radiation force impulse from 25 patients prior to and 2, 7, and 14 days after chemotherapy. Progression-free survival (PFS) after chemotherapy was estimated using the Kaplan-Meier method. The Cox proportional hazard regression model was used to determine significant predictive factors for PFS. For measurement reproducibility, an additional 37 patients with CRLMs were enrolled and assessed using intraclass correlation coefficients (ICCs).

RESULTS: After chemotherapy, 10 and 15 patients were classified into responder and non-responder groups, respectively. The estimated 1- and 3-year PFS values in the whole cohort were 36% and 8%, respectively. A decrease in the SWV value on day 2 relative to the initial value was a significant predictive factor for better PFS outcome (hazard ratio = 0.20, 95% confidence interval = 0.07-0.57, p=0.003). The estimated 1 and 3-year PFS rates were 66.7% and 22.2%, respectively, in nine patients with decreased SWV values on day 2 and significantly higher than 18.8% and 0% of 16 patients with increased SWV values on day 2. The ICC value of SWV of CRLMs in the additional 37 patients was 0.823 (95% CI = 0.685-0.905), indicating good agreement.

CONCLUSION: SWV values of CRLMs could provide prognostic information in patients with CRLMs treated with chemotherapy, as decreased SWV values on day 2 after chemotherapy was a significant predictive factor for better PFS.

来源:Clin Radiol,查看原文。版权归原作者所有。