文献速递腹部MR

呼吸触发小视野与全视野扩散加权成像在胰腺病变中的定性与定量比较

Qualitative and Quantitative Comparison of Respiratory Triggered Reduced Field-of-View (FOV) Versus Full FOV Diffusion Weighted Imaging (DWI) in Pancreatic Pathologies.
PubMed 文献 · Acad Radiol · 2020-12-31

本研究纳入153例疑似胰腺病变患者,比较呼吸触发全视野(fFOV,体素3×3×4 mm³)与小视野(rFOV,体素2.5×2.5×3 mm³)扩散加权成像。两位放射科医师主观评分显示rFOV图像质量各项指标均更优,表观信噪比fFOV更高而表观对比噪声比rFOV更高,两组表观扩散系数值无差异。结论认为rFOV DWI图像质量和表观对比噪声比更高,有利于胰腺病变分析。

要点

  • rFOV DWI在整体图像质量、病灶 conspicuity、解剖细节及伪影方面的主观评分均优于fFOV DWI。
  • 正常胰腺、胰腺病变及参考组织的ADC值在rFOV与fFOV序列间无差异。
  • 表观信噪比fFOV更高,而表观对比噪声比rFOV更高。

核心结论

  • rFOV DWI提供更高的图像质量和表观对比噪声比,有利于胰腺病变的分析。

研究设计与样本

  • 单中心前瞻性纳入153例疑似胰腺病变患者,行临床常规MRI检查,包括呼吸触发扩散加权单次激发回波平面成像。
  • fFOV序列体素大小为3×3×4 mm³,rFOV序列体素大小为2.5×2.5×3 mm³。
  • 由两位经验丰富的放射科医师采用Likert 1-4级量表主观评分图像质量、病灶 conspicuity、解剖细节和伪影。
  • 定量评估表观扩散系数、表观信噪比和表观对比噪声比。

关键影像表现/征象

  • rFOV DWI图像在整体图像质量、病灶 conspicuity、解剖细节及伪影方面的主观评分均优于fFOV DWI,评分者间信度为中等至高度。
  • 正常胰腺、胰腺病变及参考组织的ADC值在两种序列间无差异。
  • 表观信噪比在fFOV图像中更高,而表观对比噪声比在rFOV图像中更高。

诊断标准与关键数值

  • 主观图像质量采用Likert 1-4级量表评分,rFOV各项指标评分均优于fFOV。
  • 定量参数包括ADC、表观信噪比和表观对比噪声比;ADC值在两种序列间无差异,表观信噪比fFOV更高,表观对比噪声比rFOV更高。

临床应用与阅片要点

  • 在胰腺DWI阅片时,rFOV序列可提供更优的整体图像质量、病灶 conspicuity和解剖细节,并减少伪影。
  • rFOV序列的表观对比噪声比更高,有助于胰腺病变的显示;ADC值在两种序列间无差异,解读ADC时无需因序列不同而调整。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate the effects of a reduced field-of-view (rFOV) acquisition in diffusion-weighted magnetic resonance imaging of the pancreas.

MATERIALS AND METHODS: We enrolled 153 patients who underwent routine clinical MRI work-up including respiratory-triggered diffusion-weighted single-shot echo-planar imaging (DWI) with full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) and reduced field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) for suspected pancreatic pathology. Two experienced radiologists were asked to subjectively rate (Likert Scale 1-4) image quality (overall image quality, lesion conspicuity, anatomical detail, artifacts). In addition, quantitative image parameters were assessed (apparent diffusion coefficient, apparent signal to noise ratio, apparent contrast to noise ratio [CNR]).

RESULTS: All subjective metrics of image quality were rated in favor of rFOV DWI images compared to fFOV DWI images with substantial-to-high inter-rater reliability. Calculated ADC values of normal pancreas, pancreatic pathologies and reference tissues revealed no differences between both sequences. Whereas the apparent signal to noise ratio was higher in fFOV images, apparent CNR was higher in rFOV images.

CONCLUSION: rFOV DWI provides higher image quality and apparent CNR values, favorable in the analysis of pancreatic pathologies.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Harder FN, Kamal O, Kaissis GA, et al. Qualitative and Quantitative Comparison of Respiratory Triggered Reduced Field-of-View (FOV) Versus Full FOV Diffusion Weighted Imaging (DWI) in Pancreatic Pathologies. Acad Radiol. 2020. PMID: 33390324. doi:10.1016/j.acra.2020.12.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。