前瞻性比较整合式现场CT血流储备分数与静态CT灌注联合冠状动脉CT血管成像检测限流性冠状动脉狭窄
前瞻性纳入48例患者(74支血管),比较CCTA单独、CCTA+CTP、CCTA+CT-FFR检测限流性CAD(ICA≥50%狭窄且SPECT/MPI对应灌注缺损)的诊断效能。CCTA+CT-FFR的AUC为0.92,高于CCTA的0.82(p=0.01),与CCTA+CTP(AUC=0.90)诊断准确率相当。
要点
- CCTA+CT-FFR检测限流性狭窄的AUC为0.92,高于CCTA单独0.82(p=0.01)。
- CCTA+CT-FFR与CCTA+CTP诊断准确率相当(AUC 0.92 vs 0.90)。
- 现场CT-FFR基于静息CCTA数据计算,无需额外血管扩张剂、对比剂和辐射暴露。
核心结论
- 现场CT-FFR联合CCTA在识别ICA+SPECT/MPI定义的限流性CAD方面,较CCTA单独提供增量诊断改善。
- 整合CTP与CCTA的诊断准确率与CCTA+CT-FFR相当。
研究设计与样本
- 前瞻性研究,纳入48例患者(74支血管),在研究指定的联合CTA-CTP检查及SPECT/MPI后行常规冠状动脉造影。
- 采用320排CT扫描仪,时间分辨率137 ms。
- CT-FFR使用静息CCTA数据,通过专用工作站软件现场计算。
- 五种成像模态均在盲法独立核心实验室分析。
- 限流性狭窄定义为ICA示阻塞性(≥50%)狭窄且SPECT/MPI负荷灌注缺损对应。
诊断标准与关键数值
- 限流性CAD定义:ICA示≥50%阻塞性狭窄且SPECT/MPI对应负荷灌注缺损。
- ICA+SPECT/MPI定义的阻塞性CAD患病率为40%。
- 每支血管敏感度与特异度:CCTA为95%和42%,CCTA+CTP为76%和89%,CCTA+CT-FFR为81%和96%。
- CCTA的AUC为0.82,联合CT-FFR后AUC为0.92(p=0.01;IDI=0.27,p<0.001)。
- CCTA联合CTP后AUC为0.90(p=0.02;IDI=0.18,p=0.003)。
临床应用与阅片要点
- CT-FFR与CTP均可联合CCTA提高对限流性狭窄的检测准确率,CT-FFR特异度更高(96% vs 89%),CTP敏感度更高(89% vs 76%)。
- 单一增宽CCTA数据采集可同时获得解剖与生理信息,无需额外血管扩张剂、对比剂和辐射暴露。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the diagnostic power of separately integrating on-site computed tomography (CT)-derived fractional flow reserve (CT-FFR) and static CT stress myocardial perfusion (CTP) with coronary computed tomography angiography (CCTA) in detecting patients with flow-limiting CAD. The flow-limiting stenosis was defined as obstructive (≥ 50%) stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI).
METHODS: Forty-eight patients (74 vessels) were enrolled who underwent research-indicated combined CTA-CTP (320-row CT scanner, temporal resolution 137 ms) and SPECT/MPI prior to conventional coronary angiography. CT-FFR was computed on-site using resting CCTA data with dedicated workstation-based software. All five imaging modalities were analyzed in blinded independent core laboratories. Logistic regression and the integrated discrimination improvement (IDI) index were used to evaluate incremental differences in CT-FFR or CTP compared with CCTA alone.
RESULTS: The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI was 40%. Per-vessel sensitivity and specificity were 95 and 42% for CCTA, 76 and 89% for CCTA + CTP, and 81 and 96% for CCTA + CT-FFR, respectively. The diagnostic performance of CCTA (AUC = 0.82) was improved by combining it with CT-FFR (AUC = 0.92, p = 0.01; IDI = 0.27, p < 0.001) or CTP (AUC = 0.90, p = 0.02; IDI = 0.18, p = 0.003).
CONCLUSION: On-site CT-FFR combined with CCTA provides an incremental diagnostic improvement over CCTA alone in identifying patients with flow-limiting CAD defined by ICA + SPECT/MPI, with a comparable diagnostic accuracy for integrated CTP and CCTA.
KEY POINTS: • Both on-site CT-FFR and CTP perform well with high diagnostic accuracy in the detection of flow-limiting stenosis. • Comparable diagnostic accuracy between CCTA + CT-FFR and CCTA + CTP is demonstrated to detect flow-limiting stenosis. • Integrated CT-FFR and CCTA derived from a single widened CCTA data acquisition can accurately and conveniently evaluate both coronary anatomy and physiology in the future management of patients with suspected CAD, without the need for additional vasodilator administration and contrast and radiation exposure.
引用
- Guo W, Lin Y, Taniguchi A, et al. Prospective comparison of integrated on-site CT-fractional flow reserve and static CT perfusion with coronary CT angiography for detection of flow-limiting coronary stenosis. Eur Radiol. 2021. PMID: 33409778. doi:10.1007/s00330-020-07508-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。