超声介导微泡空化通过eNOS/NO通路增强微循环灌注短暂逆转急性后肢组织缺血
研究在大鼠急性后肢缺血模型中比较超声联合微泡、单纯超声和单纯微泡的效果,用超声造影灌注成像评估。超声联合微泡组缺血后肢微血管血容量和血流量显著增加,效应于治疗后即刻出现并于25分钟消退,eNOS/NO通路似乎介导该效应。
要点
- 超声联合微泡可短暂增加急性缺血后肢的微血管血容量和血流量,效应于25分钟消退。
- 单纯超声和单纯微泡组变化很小。
- eNOS/NO通路似乎介导超声空化增加缺血组织灌注的效应。
关键影像表现/征象
- US+MB组缺血后肢微血管血容量和微血管血流量在治疗后显著增加(两者p值均<0.05)。
- US+MB组微血管通量率(β)增加但未达统计学显著(p>0.05)。
- 上述增加在治疗后即刻观察到,并在25分钟时消退。
- US组和MB组变化很小。
诊断标准与关键数值
- 采用超声造影灌注成像评估双后肢灌注,于治疗后即刻及治疗后5、10、15、20、25分钟进行。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ultrasound-mediated microbubble cavitation improves perfusion in chronic limb and myocardial ischemia. The purpose of this study was to determine the effects of ultrasound-mediated microbubble cavitation in acute limb ischemia and investigate the mechanism of action. The animal with acute hindlimb ischemia was established using male Sprague-Dawley rats. The rats were randomly divided into three groups: intermittent high-mechanical-index ultrasound pulses combined with microbubbles (ultrasound [US] + MB group), US alone (US group) and MB alone (MB group). Both hindlimbs were treated for 10 min. Contrast ultrasound perfusion imaging of both hindlimbs was performed immediately and 5, 10, 15, 20 and 25 min after treatment. The role of the nitric oxide (NO) pathway in increasing blood flow in acutely ischemic tissue was evaluated by inhibiting endothelial nitric oxide synthase (eNOS) with Nω-nitro-L-arginine methyl ester hydrochloride (L-NAME). In the US + MB group, microvascular blood volume and microvascular blood flow of the ischemic hindlimb were significantly increased after treatment (both p values <0.05), while the microvascular flux rate (β) increased, but not significantly (p > 0.05). The increases were observed immediately after treatment, and had dissipated by 25 min. Changes in the US and MB groups were minimal. Inhibitory studies indicated cavitation increased phospho-eNOS concentration in ischemic hindlimb muscle tissue, and the increase was significantly inhibited by L-NAME (p < 0.05). Ultrasound-mediated microbubble cavitation transiently increases local perfusion in acutely ischemic tissue, mainly by improving microcirculatory perfusion. The eNOS/NO signaling pathway appears to be an important mediator of the effect.
引用
- Qiu S, Li D, Wang Y, et al. Ultrasound-Mediated Microbubble Cavitation Transiently Reverses Acute Hindlimb Tissue Ischemia through Augmentation of Microcirculation Perfusion via the eNOS/NO Pathway. Ultrasound Med Biol. 2021. PMID: 33487472. doi:10.1016/j.ultrasmedbio.2020.12.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。