文献速递心血管技术与安全PETCT

全球核心脏病学相机技术、重建软件与成像方案使用差异

Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols.
PubMed 文献 · JACC Cardiovasc Imaging · 2021-01-13

该跨国横断面研究纳入65国308个实验室的7911例心肌灌注显像,比较各地区相机技术、后处理软件和方案特征及其对有效剂量的影响。镉锌碲相机和PET相机全球使用率分别为10%和6%,衰减校正26%,先进后处理软件38%;应激首过SPECT在北美仅7%。新技术和应激-only方案与较低有效剂量相关,但全球采用率普遍较低且地区差异显著。

要点

  • 全球仅39%研究有效剂量≤9 mSv(PET 97%、SPECT 35%),仅6%≤3 mSv(PET 32%、SPECT 4%)。
  • 镉锌碲相机、PET、先进后处理软件和应激-only或静息-only方案与较低有效剂量及≤9 mSv的更高几率相关。
  • 应激首过SPECT除北美(7%)外各区域约占20%,新技术全球采用率普遍较低且地区差异大。

诊断标准与关键数值

  • 镉锌碲相机全球使用率10%(地区范围0%至26%),PET相机6%(地区范围0%至17%)。
  • 衰减校正使用率26%(范围10%至57%),先进后处理软件使用率38%(范围26%至64%)。
  • 应激首过SPECT占所有区域约20%,北美仅7%。
  • 总体39%研究有效剂量≤9 mSv(PET 97%、SPECT 35%),仅6%研究≤3 mSv(PET 32%、SPECT 4%)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED).

BACKGROUND: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols.

METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED.

RESULTS: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv.

CONCLUSIONS: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Hirschfeld CB, Mercuri M, Pascual TNB, et al. Worldwide Variation in the Use of Nuclear Cardiology Camera Technology, Reconstruction Software, and Imaging Protocols. JACC Cardiovasc Imaging. 2021. PMID: 33454257. doi:10.1016/j.jcmg.2020.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。