肾下腹主动脉四维超声检查的观察者内与观察者间变异性

Intra- and Interobserver Variability of 4D Ultrasound Examination of the Infrarenal Aorta.
PubMed 文献 · J Ultrasound Med · 2021-01-16

本研究纳入22例非动脉瘤性腹主动脉患者,由经验丰富检查者和医学生分别行四维超声检查,评估观察者内重复性与观察者间可重复性。结果显示最大主动脉直径与周向应变在全部患者及非动脉粥样硬化主动脉中可靠性很好(ICC>0.7),但钙化主动脉周向应变可靠性低(ICC=0.29)。

要点

  • 四维超声测量非动脉瘤性腹主动脉最大直径与周向应变可靠性很好(ICC>0.7)。
  • 钙化主动脉的周向应变可靠性低(ICC=0.29),判读需谨慎。
  • 观察者经验与掩膜相关方差接近零,提示测量受操作者经验影响小。

核心结论

  • 尽管测量值较低,四维超声凭借高空间与时间分辨率,可可靠评估非动脉瘤性腹主动脉的周期性直径变化与周向应变,且不依赖观察者经验,但对钙化主动脉存在一定局限。
  • 四维超声为非侵入性在体评估腹主动脉血管壁运动学特性开辟了新视角。

研究设计与样本

  • 研究纳入22例非动脉瘤性腹主动脉患者,由一名经验丰富检查者和一名医学生分别行四维超声检查。
  • 配准四维图像后,两名检查者手动标记主动脉壁,再应用商用斑点追踪算法,并用自制软件测定主动脉直径与周向应变的周期性变化。
  • 采用组内相关系数(ICC)检验四维超声的可靠性。

诊断标准与关键数值

  • 最大主动脉直径与周向应变在全部患者及非动脉粥样硬化主动脉中ICC均>0.7,判为可靠性很好。
  • 钙化主动脉的周向应变ICC=0.29,判为可靠性低。
  • 最大直径与周向应变的观察者相关及掩膜相关方差均接近零。

临床应用与阅片要点

  • 四维超声可用于非动脉瘤性腹主动脉直径周期性变化与周向应变的在体评估,观察者经验对测量影响小。
  • 对钙化主动脉行周向应变评估时可靠性低(ICC=0.29),解读结果需结合钙化情况。

局限性

  • 原文指出四维超声在低测量值下的在体可靠性此前未知,本研究对此进行验证。
  • 原文指出该方法对钙化主动脉存在一定局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The four-dimensional ultrasound (4D-US) enables imaging of the aortic segment and simultaneous determination of the wall expansion. The method shows a high spatial and temporal resolution, but its in vivo reliability is so far unknown for low-measure values. The present study determines the intraobserver repeatability and interobserver reproducibility of 4D-US in the atherosclerotic and non-atherosclerotic infrarenal aorta.

METHODS: In all, 22 patients with non-aneurysmal aorta were examined by an experienced examiner and a medical student. After registration of 4D images, both the examiners marked the aortic wall manually before the commercially implemented speckle tracking algorithm was applied. The cyclic changes of the aortic diameter and circumferential strain were determined with the help of custom-made software. The reliability of 4D-US was tested by the intraclass correlation coefficient (ICC).

RESULTS: The 4D-US measurements showed very good reliability for the maximum aortic diameter and the circumferential strain for all patients and for the non-atherosclerotic aortae (ICC >0.7), but low reliability for circumferential strain in calcified aortae (ICC = 0.29). The observer- and masking-related variances for both maximum diameter and circumferential strain were close to zero.

CONCLUSIONS: Despite the low-measured values, the high spatial and temporal resolution of the 4D-US enables a reliable evaluation of cyclic diameter changes and circumferential strain in non-aneurysmal aortae independent from the observer experience but with some limitations for calcified aortae. The 4D-US opens up a new perspective with regard to noninvasive, in vivo assessment of kinematic properties of the vessel wall in the abdominal aorta.

来源:J Ultrasound Med,查看原文。版权归原作者所有。