基于CT数字重建放射影像训练的深度卷积神经网络在胸片上自动检测和量化COVID-19气腔病变:达到专家放射科医师水平的新方法
本研究回顾性纳入86例COVID-19患者,以CT手动分割的气腔病变体积百分比为金标准,投影至数字重建放射影像训练卷积神经网络,在胸片上量化气腔病变。CNN的平均绝对误差为9.56%~9.78%,相关系数为0.78~0.81,与专家放射科医师水平相当。
要点
- CNN在胸片上量化COVID-19气腔病变的相关系数为0.78~0.81,与专家读者相当。
- CNN的平均绝对误差为9.56%~9.78%,低于专家读者的11.98%。
- 该方法以CT体积定量为金标准,通过数字重建放射影像训练,可用于胸片评估。
核心结论
- 以CT气腔病变定量为金标准、经数字重建放射影像训练的CNN,在逆转录聚合酶链反应阳性COVID-19患者的胸片气腔病变量化中达到专家放射科医师水平的准确度。
研究设计与样本
- 回顾性队列研究,纳入2020年3月至5月美国东北部一家三级医院的86例COVID-19患者(逆转录聚合酶链反应阳性),均在48小时内接受胸部CT和胸片检查。
- 以CT手动分割气腔病变获得的体积百分比(POv)为金标准,将三维掩模投影至二维前后位数字重建放射影像计算面积气腔病变百分比(POa)。
- CNN在更大规模COVID-19及非COVID-19患者CT数据集生成的数字重建放射影像上训练,自动分割肺、气腔病变并量化胸片上的POa。
- 将CNN的POa结果与2位专家读者在胸片上量化的POa及POv金标准比较,计算相关性和平均绝对误差。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to leverage volumetric quantification of airspace disease (AD) derived from a superior modality (computed tomography [CT]) serving as ground truth, projected onto digitally reconstructed radiographs (DRRs) to (1) train a convolutional neural network (CNN) to quantify AD on paired chest radiographs (CXRs) and CTs, and (2) compare the DRR-trained CNN to expert human readers in the CXR evaluation of patients with confirmed COVID-19.
MATERIALS AND METHODS: We retrospectively selected a cohort of 86 COVID-19 patients (with positive reverse transcriptase-polymerase chain reaction test results) from March to May 2020 at a tertiary hospital in the northeastern United States, who underwent chest CT and CXR within 48 hours. The ground-truth volumetric percentage of COVID-19-related AD (POv) was established by manual AD segmentation on CT. The resulting 3-dimensional masks were projected into 2-dimensional anterior-posterior DRR to compute area-based AD percentage (POa). A CNN was trained with DRR images generated from a larger-scale CT dataset of COVID-19 and non-COVID-19 patients, automatically segmenting lungs, AD, and quantifying POa on CXR. The CNN POa results were compared with POa quantified on CXR by 2 expert readers and to the POv ground truth, by computing correlations and mean absolute errors.
RESULTS: Bootstrap mean absolute error and correlations between POa and POv were 11.98% (11.05%-12.47%) and 0.77 (0.70-0.82) for average of expert readers and 9.56% to 9.78% (8.83%-10.22%) and 0.78 to 0.81 (0.73-0.85) for the CNN, respectively.
CONCLUSIONS: Our CNN trained with DRR using CT-derived airspace quantification achieved expert radiologist level of accuracy in the quantification of AD on CXR in patients with positive reverse transcriptase-polymerase chain reaction test results for COVID-19.
引用
- Mortani Barbosa EJ, Gefter WB, Ghesu FC, et al. Automated Detection and Quantification of COVID-19 Airspace Disease on Chest Radiographs: A Novel Approach Achieving Expert Radiologist-Level Performance Using a Deep Convolutional Neural Network Trained on Digital Reconstructed Radiographs From Computed Tomography-Derived Ground Truth. Invest Radiol. 2021. PMID: 33481459. doi:10.1097/RLI.0000000000000763
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。