影像引导下胸腔引流管置入治疗儿童心脏术后乳糜胸:单中心病例系列
该单中心回顾性病例系列分析34例儿童37个心脏术后乳糜胸,共行48次引流操作、置入53根影像引导胸腔引流管(2004—2015年)。影像引导引流管中位留置21天,无严重不良事件,26/37(70%)影像学缓解,23例(68%)存活出院,11例(32%)死于基础心脏病。
要点
- 儿童心脏术后乳糜胸可经影像引导胸腔引流管处理,中位留置21天,无严重不良事件。
- 引流管相关不良事件以轻度为主(8例轻度、3例中度、0例重度)。
- 影像学缓解26/37(70%),但总体病死率仍高(11/34,32%死于基础心脏病)。
关键影像表现/征象
- 53根引流管中单侧单管29例儿童(43/53,81%),双侧4例(8/53,15%),同侧双管1例(2/53,4%)。
- 积液呈包裹性者33/53(62%);48次操作中积液呈分隔/复杂者20/48(42%)。
诊断标准与关键数值
- 影像引导胸腔引流管首24小时平均引流量17.3 mL/kg,自诊断至拔管平均13.4 mL/kg/天,所有胸腔引流管总平均引流量19.6 mL/kg/天。
- 影像引导引流管中位留置时间21天(范围4—57天)。
- 影像学缓解26/37(70%)。
- 引流管相关不良事件:轻度8例、中度3例、重度0例。
- 1,207管日内需主要维护操作9次、次要维护操作27次(维护率30次/1,000管日)。
临床应用与阅片要点
- 影像引导胸腔引流管置入前,多数患儿已接受饮食限制(32/37,86%)、奥曲肽(12/37,32%)、类固醇(7/37,19%)或胸导管结扎(5/37,14%)。
- 作者认为多次影像引导胸腔引流管引流可帮助实现缓解且并发症少,介入放射科需参与引流管护理与维护。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: In children, chylothorax post cardiac surgery can be difficult to treat, may run a protracted course, and remains a source of morbidity and mortality.
OBJECTIVE: To analyze the experience with percutaneous image-guided chest-tube drainage in the management of post-cardiac-surgery chylothoraces in children.
MATERIALS AND METHODS: We conducted a single-center retrospective case series of 37 post-cardiac-surgery chylothoraces in 34 children (20 boys; 59%), requiring 48 drainage procedures with placement of 53 image-guided chest tubes over the time period 2004 to 2015. We analyzed clinical and procedural details, adverse events and outcomes. Median age was 0.6 years, median weight 7.2 kg.
RESULTS: Attempted treatments of chylothoraces prior to image-guided chest tubes included dietary restrictions (32/37, 86%), octreotide (12/37, 32%), steroids (7/37, 19%) and thoracic duct ligation (5/37, 14%). Image-guided chest tubes (n=43/53, 81%) were single unilateral in 29 children, bilateral in 4 (n=8/53, 15%), and there were two ipsilateral tubes in one (2/53, 4%). Effusions were isolated, walled-off, in 33/53 (62%). In 20/48 procedures (42%) effusions were septated/complex. The mean drainage through image-guided chest tubes was 17.3 mL/kg in the first 24 h, and 13.4 mL/kg/day from diagnosis to chest tube removal; total mean drainage from all chest tubes was 19.6 mL/kg/day. Nine major and 27 minor maintenance procedures were required during 1,207 tube-days (rate: 30 maintenance/1,000 tube-days). Median tube dwell time was 21 days (range 4-57 days). There were eight mild adverse events, three moderate adverse events and no severe adverse events related to image-guided chest tubes. Radiologic resolution was achieved in 26/37 (70%). Twenty-three children (68%) survived to discharge; 11 children (32%) died from underlying cardiac disease.
CONCLUSION: Management of chylothorax post-cardiac-surgery in children is multidisciplinary, requiring concomitant multipronged approaches, often through a protracted course. Multiple image-guided chest tube drainages can help achieve resolution with few complications. Interventional radiology involvement in tube care and maintenance is required. Overall, mortality remains high.
引用
- Adil O, Russell JL, Khan WU, et al. Image-guided chest tube drainage in the management of chylothorax post cardiac surgery in children: a single-center case series. Pediatr Radiol. 2021. PMID: 33515053. doi:10.1007/s00247-020-04928-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。