利用三维软件对多排CT评估矽肺患者肺密度与体积变化及其与密集度评分的关系
回顾性比较44例矽肺患者与32例因外伤行胸部CT的对照者,用三维软件获取全肺体积、全肺平均密度、肺高密度区百分比等参数,并按ILO分类分级。矽肺组与对照组全肺平均密度无显著差异(p=0.213),全肺体积差异显著(p<0.0001);肺高密度区百分比与疾病严重程度强相关(r=0.804),高密度区百分比在各ILO严重程度分级间差异显著(p=0.000005)。
要点
- 全肺体积在矽肺组与对照组间差异显著(p<0.0001),全肺平均密度无显著差异(p=0.213)。
- 肺高密度区百分比与ILO疾病严重程度强相关(r=0.804,p<0.0001)。
- 肺高密度区百分比在各ILO严重程度分级间差异显著(p=0.000005)。
核心结论
- 全肺体积是反映结晶性二氧化硅暴露变化的CT指标。
- 多排CT测得的肺高密度区百分比是评估疾病严重程度的有效参数。
研究设计与样本
- 回顾性研究,纳入44例确诊矽肺患者与32例因外伤行胸部CT的对照者。
- 采用多排CT扫描,并用三维软件测量全肺体积、全肺平均密度、肺高密度区百分比、肺密度评分及上、下叶平均密度。
- 矽肺患者按国际劳工组织(ILO)分类分为三类。
关键影像表现/征象
- 矽肺组与对照组全肺平均密度无显著差异(p=0.213)。
- 矽肺组与对照组全肺体积差异显著(p<0.0001)。
诊断标准与关键数值
- 按ILO分类的疾病严重程度分级间,肺高密度区百分比差异显著(p=0.000005),严重程度与高密度区百分比强相关(p<0.0001,r=0.804)。
- 按ILO分类的疾病严重程度分级间,肺密度评分差异显著(p=0.000144),严重程度与肺密度评分中度相关(p<0.0001,r=0.580)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the density and volume changes in the lungs of silicosis patients and their relationship with the disease severity classification of the International Labor Organization (ILO).
MATERIALS AND METHODS: The multidetector computed tomography (CT) images of 44 patients diagnosed with silicosis and 32 controls that underwent thoracic CT due to trauma were evaluated. Patients with silicosis were divided into three categories according to the ILO classification. Data related to the total lung volume, total lung mean density, lung opacity score, percentage of lung high opacity, and mean density in the lower and upper lobes were obtained using three-dimensional (3D) software.
RESULTS: There was no significant difference between the total lung mean densities of the silicosis and control groups (p=0.213); however, a significant difference was observed between the two groups in terms of the total lung volume (p<0.0001). According to the ILO classification, there was a significant difference between the disease severity categories in relation to the percentage of lung high opacity (p=0.000005). A strong correlation was detected between disease severity and high opacity percentage (p<0.0001, r=0.804). According to the ILO classification, there was also a significant difference between disease severity categories in terms of the lung opacity score (p=0.000144), as well as a moderate correlation between disease severity and opacity score (p<0.0001, r=0.580).
CONCLUSION: Total lung volume is a CT finding that shows variation in exposure to crystalline silica. The percentage of high opacity determined using multidetector CT is an effective parameter in evaluating disease severity.
引用
- Çankaya BY, Polat G, Tezcan A, et al. Evaluation of lung densitometric and volumetric changes in silicosis patients using three-dimensional software for multidetector CT and the relationship with profusion scores. Clin Radiol. 2021. PMID: 33509607. doi:10.1016/j.crad.2020.12.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。