研究纳入53例胸主动脉血管成像患者,均行非门控和心电图门控对比增强MR血管成像,两名阅片者独立测量窦部、窦管交界、升主动脉、远端主动脉弓和降主动脉的血管直径、图像质量和血管锐利度。心电图门控在多个层面的图像质量评分显著更高,且在窦部和升主动脉的观察者间及观察者内变异显著更小。作者认为心电图门控对比增强MR血管成像应被用于升胸主动脉的系列评估。

要点

  • 心电图门控对比增强MR血管成像在窦部、窦管交界、升主动脉、远端主动脉弓和降主动脉的图像质量评分均显著高于非门控。
  • 窦部和升主动脉的观察者间及观察者内变异在心电图门控下显著更小。
  • 非门控窦部测量的95%一致性界限超过外科修复的生长速率阈值0.5 cm。

关键影像表现/征象

  • 心电图门控的图像质量评分在窦部为3.2 ± 0.9,非门控为1.2 ± 1.0(p < 0.0001)。
  • 心电图门控的图像质量评分在窦管交界为3.4 ± 0.7,非门控为1.8 ± 1.0(p < 0.0001)。
  • 心电图门控的图像质量评分在升主动脉为3.5 ± 0.6,非门控为1.7 ± 1.1(p < 0.0001)。
  • 心电图门控的图像质量评分在远端主动脉弓为4.0 ± 0.1,非门控为3.6 ± 0.7(p = 0.006)。
  • 心电图门控的图像质量评分在降主动脉为4.0 ± 0.1,非门控为3.4 ± 0.9(p < 0.0001)。

诊断标准与关键数值

  • Bland-Altman分析显示,窦部和升主动脉的观察者间及观察者内变异在心电图门控MR血管成像下显著更小。
  • 非门控图像在窦部的观察者间和观察者内变异95%一致性界限均超过外科修复的生长速率阈值0.5 cm。
  • 在降主动脉,两种技术的变异相似。

临床应用与阅片要点

  • 作者建议心电图门控对比增强MR血管成像用于升胸主动脉的系列评估。
  • 非门控对比增强MR血管成像时,近端主动脉的搏动运动导致测量可重复性出现显著变异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Cardiac motion and aortic pulsatility can affect the image quality of 3D contrast-enhanced MR angiography (CE-MRA). The addition of ECG gating improves image quality; however, no studies have directly linked image quality improvements to clinically used measures. In this study, we directly compared diameter measurements in the same patient from ECG-gated to non-gated CE-MRA to evaluate the impact of ECG gating upon measurement reproducibility.

METHODS: Fifty-three patients, referred for thoracic aortic angiography, were enrolled and underwent both non-gated and ECG-gated CE-MRA. Two readers independently measured vessel diameter, image quality, and vessel sharpness at the sinus of Valsalva (SOV), sinotubular junction (STJX), ascending aorta (AAO), distal aortic arch (DLSA), and descending aorta (DAO). Measurement reliability and reproducibility were compared between methods.

RESULTS: Image quality with ECG gating was rated significantly higher at the SOV (3.2 ± 0.9 vs 1.2 ± 1.0, p < 0.0001), STJX (3.4 ± 0.7 vs 1.8 ± 1.0, p < 0.0001), AAO (3.5 ± 0.6 vs 1.7 ± 1.1 p < 0.0001), DLSA (4.0 ± 0.1 vs 3.6 ± 0.7, p = 0.006), and DAO (4.0 ± 0.1 vs 3.4 ± 0.9 p < 0.0001) than for non-gated studies. Bland-Altman analyses demonstrated that inter- and intra-observer variability was significantly smaller for ECG-gated MRA at the SOV and AAO. For the non-gated images at the SOV, the 95% limits of agreement for both inter- and intra-observer variability exceeded the growth-rate cutoff for surgical repair (0.5 cm). At the DAO, variability was similar between the two techniques.

CONCLUSION: ECG-gated CE-MRA resulted in improved reproducibility in aortic root and ascending aortic measurements. These data suggest that ECG-gated CE-MRA should be used for the serial assessment of the ascending thoracic aorta.

KEY POINTS: • ECG-gated CE-MRA improves the reproducibility and repeatability of measurements of the ascending aorta. • With non-gated CE-MRA, pulsatile motion in the proximal aorta results in significant variability in measurement reproducibility.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Smith LR, Darty SN, Jenista ER, et al. ECG-gated MR angiography provides better reproducibility for standard aortic measurements. Eur Radiol. 2021. PMID: 33409772. doi:10.1007/s00330-020-07408-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。