CT重建设置对基于深度学习的肺结节CAD系统性能的影响
本研究回顾性分析24例胸部CT的384个重建图像,评估不同重建参数(SAFIRE与ADMIRE两种迭代重建算法、层厚、卷积核及迭代强度)对商用深度学习肺结节CAD系统性能的影响。结果显示迭代强度增加时召回率逐渐下降、精确率提高,最佳阈值设置为0.88(F2=0.73±0.053),提示在多台CT扫描仪和不同重建方案医院中实施深度学习软件需谨慎。
要点
- 迭代重建强度增加时,DL-CAD召回率逐渐下降而精确率提高,与FBP数据表现不同。
- 在本中心临床工作流中,DL-CAD最佳阈值设置为0.88,F2为0.73±0.053。
- 多台CT扫描仪和不同重建方案下实施深度学习软件需谨慎,因重建参数影响CAD性能。
核心结论
- DL-CAD系统在迭代重建数据与FBP数据上表现不同,迭代强度增加时召回率逐渐下降、精确率提高。
- 作者认为在多台CT扫描仪和不同重建方案的医院中实施深度学习软件需谨慎。
研究设计与样本
- 回顾性分析24例胸部CT扫描,采用两种迭代重建算法(SAFIRE和ADMIRE)在16种不同重建设置下重建,共分析384个CT重建图像。
- 使用商用深度学习肺结节CAD系统,在25种不同敏感度阈值设置下评估,检测结节与三位放射科医生共识阅读的参考标准匹配。
诊断标准与关键数值
- 在本文临床工作流中,DL-CAD最佳阈值设置为0.88,F2为0.73±0.053。
- 共分析24例患者的384个CT重建图像,共发现5786个结节。
- 在卷积核大小固定时,迭代强度水平增加,召回率逐渐下降、精确率提高。
临床应用与阅片要点
- 作者认为在多台CT扫描仪和不同重建方案的医院中实施深度学习软件需谨慎。
- 本研究中心在临床工作流中采用的DL-CAD最佳阈值设置为0.88。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To study the effect of different reconstruction parameter settings on the performance of a commercially available deep learning based pulmonary nodule CAD system.
MATERIALS AND METHODS: We performed a retrospective analysis of 24 chest CT scans, reconstructed at 16 different reconstruction settings for two different iterative reconstruction algorithms (SAFIRE and ADMIRE) varying in slice thickness, kernel size and iterative reconstruction level strength using a commercially available deep learning pulmonary nodule CAD system. The DL-CAD software was evaluated at 25 different sensitivity threshold settings and nodules detected by the DL-CAD software were matched against a reference standard based on the consensus reading of three radiologists.
RESULTS: A total of 384 CT reconstructions was analysed from 24 patients, resulting in a total of 5786 found nodules. We matched the detected nodules against the reference standard, defined by a team of thoracic radiologists, and showed a gradual drop in recall, and an improvement in precision when the iterative strength levels were increased for a constant kernel size. The optimal DL-CAD threshold setting for use in our clinical workflow was found to be 0.88 with an F2 of 0.73 ± 0.053.
CONCLUSIONS: The DL-CAD system behaves differently on IR data than on FBP data, there is a gradual drop in recall, and growth in precision when the iterative strength levels are increased. As a result, caution should be taken when implementing deep learning software in a hospital with multiple CT scanners and different reconstruction protocols. To the best of our knowledge, this is the first study that demonstrates this result from a DL-CAD system on clinical data.
引用
- Blazis SP, Dickerscheid DBM, Linsen PVM, et al. Effect of CT reconstruction settings on the performance of a deep learning based lung nodule CAD system. Eur J Radiol. 2021. PMID: 33453573. doi:10.1016/j.ejrad.2021.109526
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。