文献速递胸部MR

肺部MRI影像组学与机器学习:病灶内异质性对病灶分类的影响

Pulmonary MRI Radiomics and Machine Learning: Effect of Intralesional Heterogeneity on Classification of Lesion.
PubMed 文献 · Acad Radiol · 2021-01-22

本研究纳入176例接受多参数MRI的患者,构建基于病灶内五个亚病灶的肿瘤异质性影像组学模型,并与基于整个肿瘤的常规影像组学模型比较。肿瘤异质性模型在有无嵌套的3折交叉验证中AUC分别为0.74±0.04和0.90±0.03,均优于常规模型(0.68±0.04和0.87±0.03);对于大于18.80 cm³的病灶,两模型差异有统计学意义(p=0.03)。结论提示病灶内异质性影响肺部病灶分类,肿瘤异质性模型倾向于表现更好。

要点

  • 肿瘤异质性模型将每个病灶按空间位置聚类分为五个亚病灶,从多参数MRI序列提取1100个影像组学特征。
  • 肿瘤异质性模型AUC在有嵌套交叉验证中为0.90±0.03,无嵌套交叉验证中为0.74±0.04。
  • 对于大于18.80 cm³的病灶,肿瘤异质性模型与常规模型差异有统计学意义(p=0.03)。

核心结论

  • 病灶内异质性影响肺部病灶的良恶性分类,肿瘤异质性模型倾向于比常规影像组学模型表现更好。

研究设计与样本

  • 探索性研究,共纳入176例接受多参数MRI的患者。
  • 构建肿瘤异质性模型:通过聚类算法按空间位置将每个病灶分为五个亚病灶,从多参数MRI序列的五個亚病灶中提取1100个影像组学特征。
  • 采用递归特征消除法筛选特征,支持向量机分类器区分良恶性病灶,以受试者工作特征曲线下面积(AUC)评价分类性能。
  • 采用有嵌套和无嵌套的3折交叉验证分别验证模型。

诊断标准与关键数值

  • 肿瘤异质性模型AUC:有嵌套交叉验证0.74±0.04,无嵌套交叉验证0.90±0.03。
  • 常规影像组学模型(基于整个肿瘤)AUC:有嵌套交叉验证0.68±0.04,无嵌套交叉验证0.87±0.03。
  • 对于大于18.80 cm³的病灶,两模型差异有统计学意义(p=0.03)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate the effect of intralesional heterogeneity on differentiating benign and malignant pulmonary lesions, quantitative magnetic resonance imaging (MRI) radiomics, and machine learning methods were adopted.

MATERIALS AND METHODS: A total of 176 patients with multiparametric MRI were involved in this exploratory study. To investigate the effect of intralesional heterogeneity on lesion classification, a radiomics model called tumor heterogeneity model was developed and compared to the conventional radiomics model based on the entire tumor. In tumor heterogeneity model, each lesion was divided into five sublesions depending on the spatial location through clustering algorithm. From the five sublesions in multi-parametric MRI sequences, 1100 radiomics features were extracted. The recursive feature elimination method was employed to select features and support vector machine classifier was used to distinguish benign and malignant lesion. The performance of classification was evaluated with the receiver operating characteristic curve and the area under the curve (AUC) was the figure of merit. The 3-fold cross-validation (CV) with and without nesting was used to validate the model, respectively.

RESULTS: The tumor heterogeneity model (AUC = 0.74 ± 0.04 and 0.90 ± 0.03, CV with and without nesting, respectively) outperforms conventional model (AUC = 0.68 ± 0.04 and 0.87 ± 0.03). The difference between the two models is statistically significant (p = 0.03) for lesions greater than 18.80 cm3.

CONCLUSION: Intralesional heterogeneity influences the classification of pulmonary lesions. The tumor heterogeneity model tends to perform better than conventional radiomics model.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Wang X, Li X, Chen H, et al. Pulmonary MRI Radiomics and Machine Learning: Effect of Intralesional Heterogeneity on Classification of Lesion. Acad Radiol. 2021. PMID: 33495072. doi:10.1016/j.acra.2020.12.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。