文献速递胸部MR

囊性纤维化患者中超极化3He与129Xe MR成像的比较

Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients.
PubMed 文献 · Acad Radiol · 2021-01-21

研究纳入10例囊性纤维化患者,比较超极化3He与129Xe在标准梯度回波(GRE)和平衡稳态自由进动(TrueFISP)序列上的信号分布与通气缺损百分比(VDP)。129Xe与3He的VDP显著相关(ρ=0.78,p<0.0004),129Xe的VDP平均值(27.2±9.4)高于3He(24.3±6.9);作者认为选择哪种气体对整体VDP测量影响可能不大,但129Xe对更严重的肺缺损可能更敏感,尤其在使用TrueFISP序列时。

要点

  • 囊性纤维化患者中129Xe与3He的VDP显著相关(ρ=0.78,p<0.0004),提示两者测整体肺通气功能可能相当。
  • 129Xe的VDP平均值(27.2±9.4)高于3He(24.3±6.9),129Xe对更严重的肺缺损可能更敏感。
  • GRE与TrueFISP序列间VDP相关性在3He为ρ=0.98、在129Xe为ρ=0.91,序列选择影响有限。

核心结论

  • 在囊性纤维化患者中,用VDP测量整体肺功能时选择超极化129Xe或3He气体很可能无关紧要,但129Xe对更严重的肺缺损可能更敏感,尤其在使用TrueFISP序列时。

研究设计与样本

  • 研究为影像学对比研究,纳入10例囊性纤维化患者(7男/3女),均接受超极化3He和129Xe气体MR成像。
  • 其中6例同时有GRE和TrueFISP序列MRI,4例仅有GRE序列而无TrueFISP。
  • VDP定义为全肺超极化气体信号均值低于60%的肺体素百分比,在所有数据集中测量。

关键影像表现/征象

  • 129Xe与3He的VDP在GRE和TrueFISP序列上均显示显著相关(ρ=0.78,p<0.0004)。
  • 3He的GRE与TrueFISP序列间VDP相关系数ρ=0.98,129Xe为ρ=0.91。
  • 129Xe的VDP平均值(27.2±9.4)高于3He(24.3±6.9)。

诊断标准与关键数值

  • VDP计算标准:全肺超极化气体信号均值低于60%的肺体素定义为通气缺损。
  • 129Xe与3He的VDP相关性:ρ=0.78,p<0.0004(GRE和TrueFISP序列合并分析)。
  • 3He的GRE与TrueFISP间VDP相关ρ=0.98;129Xe的GRE与TrueFISP间VDP相关ρ=0.91。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: In this study, we compared hyperpolarized 3He and 129Xe images from patients with cystic fibrosis using two commonly applied magnetic resonance sequences, standard gradient echo (GRE) and balanced steady-state free precession (TrueFISP) to quantify regional similarities and differences in signal distribution and defect analysis.

MATERIALS AND METHODS: Ten patients (7M/3F) with cystic fibrosis underwent hyperpolarized gas MR imaging with both 3He and 129Xe. Six had MRI with both GRE, and TrueFISP sequences and four patients had only GRE sequence but not TrueFISP. Ventilation defect percentages (VDPs) were calculated as lung voxels with <60% of the whole-lung hyperpolarized gas signal mean and was measured in all datasets. The voxel signal distributions of both 129Xe and 3He gases were visualized and compared using violin plots. VDPs of hyperpolarized 3 He and 129 Xe were compared in Bland-Altman plots; Pearson correlation coefficients were used to evaluate the relationships between inter-gas and inter-scan to assess the reproducibility.

RESULTS: A significant correlation was demonstrated between 129Xe VDP and 3He VDP for both GRE and TrueFISP sequences (ρ = 0.78, p<0.0004). The correlation between the GRE and TrueFISP VDP for 3He was ρ = 0.98 and was ρ = 0.91 for 129Xe. Overall, 129Xe (27.2±9.4) VDP was higher than 3He (24.3±6.9) VDP on average on cystic fibrosis patients.

CONCLUSION: In patients with cystic fibrosis, the selection of hyperpolarized 129Xe or 3He gas is most likely inconsequential when it comes to measure the overall lung function by VDP although 129Xe may be more sensitive to starker lung defects, particularly when using a TrueFISP sequence.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Shammi UA, D'Alessandro MF, Altes T, et al. Comparison of Hyperpolarized 3He and 129Xe MR Imaging in Cystic Fibrosis Patients. Acad Radiol. 2021. PMID: 33487537. doi:10.1016/j.acra.2021.01.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。