腮腺唾液腺病变特征分析中的纹理分析:基于MR弥散加权成像的研究
本研究对54个腮腺病变(19个多形性腺瘤、14个Warthin瘤、14个上皮性恶性肿瘤、7个淋巴瘤)在ADC图上进行纹理分析,评估其在鉴别良恶性及区分多形性腺瘤、Warthin瘤、上皮性恶性肿瘤和淋巴瘤中的作用。长区域强调和长游程强调纹理参数有助于识别淋巴瘤并鉴别良恶性病变,但Warthin瘤和多形性腺瘤未被准确识别。
要点
- 长区域强调纹理参数>1.870提示上皮性恶性肿瘤,准确率81%;>2.630提示淋巴瘤,准确率93%。
- 长游程强调纹理参数>1.050提示上皮性恶性肿瘤,准确率79%;>1.070提示淋巴瘤,准确率93%。
- Warthin瘤和多形性腺瘤未被纹理分析准确识别。
诊断标准与关键数值
- 长区域强调截断值>1.870提示上皮性恶性肿瘤,准确率81%。
- 长区域强调截断值>2.630提示淋巴瘤,准确率93%。
- 长游程强调截断值>1.050提示上皮性恶性肿瘤,诊断准确率79%。
- 长游程强调截断值>1.070提示淋巴瘤,诊断准确率93%。
- 淋巴瘤、上皮性恶性肿瘤、Warthin瘤、多形性腺瘤及良恶性病变的平均kappa值分别为0.61、0.34、0.26、0.17和0.48。
临床应用与阅片要点
- 在ADC图上应用纹理分析时,长区域强调和长游程强调参数可能有助于提示淋巴瘤和鉴别良恶性腮腺病变。
- 作者结论指出Warthin瘤和多形性腺瘤未被准确识别。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Parotid lesions show overlaps of morphological findings, apparent diffusion coefficient (ADC) values and types of time/intensity curve. This research aimed to evaluate the role of diffusion weighted imaging texture analysis in differentiating between benign and malignant parotid lesions and in characterizing pleomorphic adenoma (PA), Warthin tumor (WT), epithelial malignancy (EM), and lymphoma (LY).
METHODS: Texture analysis of 54 parotid lesions (19 PA, 14 WT, 14 EM, and 7 LY) was performed on ADC map images. An ANOVA test was used to estimate both the difference between benign and malignant lesions and the texture feature differences among PA, WT, EM, and LY. A P-value≤0.01 was considered to be statistically significant. A cut-off value defined by ROC curve analysis was found for each statistically significant texture parameter. The diagnostic accuracy was obtained for each texture parameter with AUC ≥ 0.5. The agreement between each texture parameter and histology was calculated using the Cohen's kappa coefficient.
RESULTS: The mean kappa values were 0.61, 0.34, 0.26, 0.17, and 0.48 for LY, EM, WT, PA, and benign vs. malignant lesions respectively. Long zone emphasis cut-off values >1.870 indicated EM with an accuracy of 81 % and values >2.630 revealed LY with an accuracy of 93 %. Long run emphasis values >1.050 and >1.070 indicated EM and LY with a diagnostic accuracy of 79% and 93% respectively.
CONCLUSIONS: Long zone emphasis and long run emphasis texture parameters allowed the identification of LY and the differentiation between benign and malignant lesions. WT and PA were not accurately recognized.
引用
- Nardi C, Tomei M, Pietragalla M, et al. Texture analysis in the characterization of parotid salivary gland lesions: A study on MR diffusion weighted imaging. Eur J Radiol. 2021. PMID: 33453571. doi:10.1016/j.ejrad.2021.109529
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。