文献速递头颈技术与安全US

对比增强超声鉴别眼眶占位性病变良恶性:时间-强度曲线定量分析的附加价值

Differentiation of Malignant and Benign Orbital Space-Occupying Lesions Using Contrast-Enhanced Ultrasound: Added Value From a Time-Intensity Curve-Based Quantitative Analysis.
PubMed 文献 · J Ultrasound Med · 2021-01-20

回顾性分析111例眼眶占位性病变患者的对比增强超声信号,用SonoLiver软件构建时间-强度曲线并比较良恶性组间参数。恶性组呈快升快降模式,良性组呈快升慢降模式,IMAX、RS、DS、mTT、TTP、RT组间差异有统计学意义(P<.01),AT差异无统计学意义(P=.672)。时间-强度曲线定量分析将CEUS视觉评估的准确率从66.67%(74/111)提高到89.19%(99/111)。

要点

  • 恶性眼眶占位TIC呈快升快降,良性呈快升慢降。
  • IMAX、RS、DS、mTT、TTP、RT在良恶性组间差异有统计学意义(P<.01),AT无统计学差异(P=.672)。
  • TIC定量分析将CEUS鉴别良恶性的准确率从66.67%(74/111)提高到89.19%(99/111)。

关键影像表现/征象

  • 恶性组时间-强度曲线表现为信号强度快升快降。
  • 良性组时间-强度曲线表现为信号强度快升慢降。

诊断标准与关键数值

  • IMAX=427.20、DS=34.72、mTT=33.55为鉴别良恶性眼眶占位性病变的最佳截断值。
  • CEUS视觉评估鉴别良恶性的准确率为66.67%(74/111),TIC定量分析提高至89.19%(99/111)。
  • IMAX、RS、DS、mTT、TTP、RT在良恶性组间差异有统计学意义(P<.01),AT差异无统计学意义(P=.672)。

临床应用与阅片要点

  • TIC定量分析可提高CEUS鉴别眼眶占位性病变良恶性的准确率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the value of time-intensity curve (TIC) analysis of contrast-enhanced ultrasound (CEUS) signal to differentiate malignant from benign orbital space-occupying lesions.

METHODS: The CEUS signal of 111 patients with orbital space-occupying lesions was retrospectively analyzed using SonoLiver software. TIC-related parameters such as the arrival time (AT), rise time (RT), time to peak (TTP), maximum intensity (IMAX), mean transit time (mTT), slope of the increase (RS), and slope of the decrease (DS) were compared between the malignant and benign groups. Receiver operating characteristic (ROC) curve analysis was used to acquire the cutoff values of these parameters for differential diagnosis.

RESULTS: TIC patterns were characterized by fast increase and fast decrease in signal intensity in the malignant group, fast increase and a slow decrease in signal intensity in the benign group. The differences in the IMAX, RS, DS, mTT, TTP, and RT between the 2 groups were statistically significant (p <.01), while the difference in the AT were not (p = .672). ROC curve analysis showed that IMAX = 427.20, DS = 34.72, and mTT = 33.55 were the best cutoff values for differential diagnosis of malignant and benign space-occupying lesions. The accuracy rate of CEUS visual evaluation for differential diagnosis was 66.67% (74/111), while TIC quantitative analysis could effectively improve the accuracy to 89.19% (99/111).

CONCLUSIONS: TIC analysis can improve CEUS efficiency to differentiate malignant from benign orbital space-occupying lesions.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Deng Q, Sun B, et al. Differentiation of Malignant and Benign Orbital Space-Occupying Lesions Using Contrast-Enhanced Ultrasound: Added Value From a Time-Intensity Curve-Based Quantitative Analysis. J Ultrasound Med. 2021. PMID: 33470432. doi:10.1002/jum.15636

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。