文献速递神经技术与安全CTMR

贝叶斯估计算法与奇异值分解算法在80排CT灌注成像评估急性缺血性卒中中的比较

Comparison of a Bayesian estimation algorithm and singular value decomposition algorithms for 80-detector row CT perfusion in patients with acute ischemic stroke.
PubMed 文献 · Radiol Med · 2021-01-19

本研究对36例急性缺血性卒中患者的CT灌注数据,分别用标准SVD算法、重表述SVD算法和贝叶斯估计算法处理,比较定量参数的相关性与统计学差异,并用随访DWI推导的梗死体积评估 agreement。贝叶斯估计算法与标准SVD算法的CBF和MTT相关性更好,回归线斜率与截距接近理想,提示其可能更好地界定异常灌注区并准确估计梗死体积。

要点

  • 贝叶斯估计算法与标准SVD算法的CBF和MTT相关性(ρ=0.78和0.80)优于与重表述SVD算法的相关性(ρ=0.59和0.39)。
  • 仅在使用重表述SVD算法时MTT在患侧与对侧间无显著差异(p=0.217)。
  • 贝叶斯估计算法与随访DWI推导梗死体积的回归线斜率与截距接近理想(y=2.42x-6.51;ρ=0.60,p<0.001)。

诊断标准与关键数值

  • 贝叶斯估计算法与标准SVD算法的CBF相关性ρ=0.78(p<0.001),MTT相关性ρ=0.80(p<0.001)。
  • 贝叶斯估计算法与重表述SVD算法的CBF相关性ρ=0.59(p<0.001),MTT相关性ρ=0.39(p<0.001)。
  • 仅使用重表述SVD算法时,MTT在患侧与对侧间无显著差异(p=0.217)。
  • 贝叶斯估计算法估计的梗死体积与随访DWI推导梗死体积的Passing-Bablok回归方程为y=2.42x-6.51(ρ=0.60,p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: A variety of postprocessing algorithms for CT perfusion are available, with substantial differences in terms of quantitative maps. Although potential advantages of a Bayesian estimation algorithm are suggested, direct comparison with other algorithms in clinical settings remains scarce. We aimed to compare performance of a Bayesian estimation algorithm and singular value decomposition (SVD) algorithms for the assessment of acute ischemic stroke using an 80-detector row CT perfusion.

METHODS: CT perfusion data of 36 patients with acute ischemic stroke were analyzed using the Vitrea implemented a standard SVD algorithm, a reformulated SVD algorithm and a Bayesian estimation algorithm. Correlations and statistical differences between affected and contralateral sides of quantitative parameters (cerebral blood volume [CBV], cerebral blood flow [CBF], mean transit time [MTT], time to peak [TTP] and delay) were analyzed. Agreement of the CT perfusion-estimated and the follow-up diffusion-weighted imaging-derived infarct volume were evaluated by nonparametric Passing-Bablok regression analysis.

RESULTS: CBF and MTT of the Bayesian estimation algorithm were substantially different and showed a better correlation with the standard SVD algorithm (ρ = 0.78 and 0.80, p < 0.001) than with the reformulated SVD algorithm (ρ = 0.59 and 0.39, p < 0.001). There is no significant difference in MTT only when using the reformulated SVD algorithm (p = 0.217). Regarding the regression lines, the slope and intercept were nearly ideal with the Bayesian estimation algorithm (y = 2.42 x-6.51; ρ = 0.60, p < 0.001) in comparison with the SVD algorithms.

CONCLUSIONS: The Bayesian estimation algorithm can lead to a better performance compared with the SVD algorithms in the assessment of acute ischemic stroke because of better delineation of abnormal perfusion areas and accurate estimation of infarct volume.

来源:Radiol Med,查看原文。版权归原作者所有。