文献速递神经头颈儿科影像MR

使用无需对比剂的重度T2加权三维FLAIR序列评估婴儿膜迷路

Assessment of the Membranous Labyrinth in Infants Using a Heavily T2-weighted 3D FLAIR Sequence without Contrast Agent Administration.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-01-28

本研究回顾性分析10例婴儿(20耳)的脑部MR影像,其中包含无需对比剂的重度T2加权三维FLAIR颞骨扫描,由3名观察者共识评估球囊、椭圆囊及3个半规管壶腹的可见性与形态。结果显示6例(60%)MR检查质量合格,球囊、椭圆囊及壶腹可见率分别为83.3%、100%和41.6%~50.0%,形态多符合预期。结论认为该序列无需注射对比剂即可显示婴儿膜迷路,但序列采集时间降低了其在自然睡眠婴儿MR检查中的可行性。

要点

  • 无需对比剂的重度T2加权三维FLAIR可显示婴儿膜迷路结构。
  • 球囊可见率83.3%,椭圆囊可见率100%,半规管壶腹可见率41.6%~50.0%。
  • 序列采集时间影响自然睡眠婴儿MR检查的可行性。

核心结论

  • MR成像使用无需注射对比剂的重度T2加权三维FLAIR序列可显示婴儿膜迷路,但序列采集时间降低了其在自然睡眠婴儿MR检查中的可行性。

研究设计与样本

  • 回顾性研究,纳入10例婴儿(20耳),中位等效足月年龄2周(IQR 1-5周)。
  • 所有婴儿均接受脑部MR成像,包括无需对比剂的重度T2加权三维FLAIR颞骨扫描。
  • 由3名观察者共识分析每耳的球囊、椭圆囊和3个半规管壶腹的可见性与形态。

关键影像表现/征象

  • 球囊在10耳(83.3%)可见,其中9耳(90%)形态符合预期。
  • 1例先天性耳聋婴儿的1耳球囊形态不符合预期。
  • 椭圆囊在12耳(100%)可见且形态符合预期。
  • 外半规管壶腹在5耳(41.6%)可见,上半规管壶腹在6耳(50.0%)可见,后半规管壶腹在6耳(50.0%)可见,可见者形态均符合预期(100%)。
  • 6例(60%)MR检查总体质量合格(评分1或2)。

诊断标准与关键数值

  • 可见性评分:0分,不可辨认;1分,可见但边界不清;2分,可见且边界清晰。
  • 形态评分:与成人相比,分为「符合预期」或「不符合预期」。
  • 序列总体质量评分:0分,不合格;1分,合格但存在图像退化;2分,合格。

临床应用与阅片要点

  • 该序列可在无需对比剂的情况下显示婴儿膜迷路结构,球囊和椭圆囊可见率较高。
  • 半规管壶腹可见率较低(41.6%~50.0%),阅片时需注意。
  • 序列采集时间可能限制其在自然睡眠婴儿MR检查中的应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Imaging is fundamental to assessing the acoustic pathway in infants with congenital deafness. We describe our depiction of the membranous labyrinth in infants using the heavily T2-weighted 3D FLAIR sequence without a contrast agent.

MATERIALS AND METHODS: We retrospectively reviewed 10 infants (20 ears) (median term equivalent age: 2 weeks; IQR: 1-5 weeks) who had undergone brain MR imaging including a noncontrast heavily T2-weighted 3D FLAIR scan of the temporal bone. For each ear, 3 observers analyzed, in consensus, the saccule, the utricle, and the 3 ampullae, assessing the visibility (score 0, not appreciable; score 1, visible without well-defined boundaries; score 2, visible with well-defined boundaries) and morphology ("expected" or "unexpected" compared with adults). The heavily T2-weighted 3D FLAIR sequence was scored for overall quality (score 0, inadequate; score 1, adequate but with the presence of image degradation; score 2, adequate).

RESULTS: Six (60%) MR examinations were considered adequate (score 1 or 2). The saccule was visible in 10 ears (83.3%) with an expected morphology in 9 ears (90%). In 1 ear of an infant with congenital deafness, the saccule showed an unexpected morphology. The utricle was visible as expected in 12 ears (100%). The lateral ampulla was visible in 5 ears (41.6%), the superior ampulla was visible in 6 ears (50.0%), and the posterior ampulla was visible in 6 ears (50.0%), always with expected morphology (100%).

CONCLUSIONS: MR imaging can depict the membranous labyrinth in infants using heavily T2-weighted 3D FLAIR without an injected contrast agent, but the sequence acquisition time reduces its feasibility in infants undergoing MR studies during natural sleep.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Conte G, Casale S, Caschera L, et al. Assessment of the Membranous Labyrinth in Infants Using a Heavily T2-weighted 3D FLAIR Sequence without Contrast Agent Administration. AJNR Am J Neuroradiol. 2021. PMID: 33509916. doi:10.3174/ajnr.A6876

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。