双反转恢复(DIR)3T MRI上灰白质对比度降低可定位运动皮层
本研究回顾性比较双反转恢复(DIR)与T1-MPRAGE序列显示运动皮层灰白质对比度的能力,以手运动功能磁共振定位为参考。在正常半球(n=50)中,DIR的定量对比度比值(0.44)显著低于T1-MPRAGE(0.63,p<0.001);两位阅片者在正常及异常半球中均更常在DIR上判定「明确存在」灰白质对比度降低。作者认为在脑解剖扭曲的病例中,DIR可能是有助于定位运动皮层的辅助序列。
要点
- DIR上中央沟周围灰白质对比度降低较T1-MPRAGE更明显,定量对比度比值0.44 vs 0.63(p<0.001)。
- 正常半球中,阅片者1在DIR上88%、T1-MPRAGE上68%判定「明确存在」对比度降低(p=0.02);阅片者2为86% vs 64%(p=0.01)。
- 异常半球中,阅片者1在DIR上80%、T1-MPRAGE上38%判定「明确存在」(p<0.001);阅片者2为74% vs 46%(p=0.005)。
关键影像表现/征象
- DIR上中央沟周围灰白质对比度降低较T1-MPRAGE更明显,定量对比度比值DIR 0.44 vs T1-MPRAGE 0.63(p<0.001)。
- 正常半球(n=50)中,阅片者1判定「明确存在」灰白质对比度降低的比例DIR 88% vs T1-MPRAGE 68%(p=0.02);阅片者2为DIR 86% vs T1-MPRAGE 64%(p=0.01)。
- 异常半球(n=50)中,阅片者1判定「明确存在」的比例DIR 80% vs T1-MPRAGE 38%(p<0.001);阅片者2为DIR 74% vs T1-MPRAGE 46%(p=0.005)。
诊断标准与关键数值
- 定量指标为灰白质对比度比值(CR),正常半球(n=50)中DIR为0.44、T1-MPRAGE为0.63(p<0.001)。
- 定性评估采用「明确存在」灰白质对比度降低的判定,正常和异常半球中DIR的判定比例均高于T1-MPRAGE,具体数值见 findings。
临床应用与阅片要点
- 在脑解剖扭曲的病例中,DIR可能作为辅助序列用于定位运动皮层。
- 阅片时可关注中央沟周围灰白质对比度降低这一征象,DIR上较T1-MPRAGE更明显。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Reduced gray-white matter contrast along the central sulcus has been described on T1- and T2-weighted magnetic resonance imaging (MRI). The purpose of this study was to assess the gray-white matter contrast of the motor cortex on double inversion recovery (DIR), a sequence with superior gray-white matter differentiation.
METHODS: The gray-white matter signal on DIR was retrospectively compared to T1-weighted magnetization-prepared rapid gradient echo (T1-MPRAGE) using normal (n = 25) and abnormal (n = 25) functional MRI (fMRI) exams. Quantitative gray-white matter contrast ratios (CR) of the precentral and adjacent gyri were obtained on normal exams. Two neuroradiologists qualitatively rated reduced gray-white matter contrast of the hemispheres of both normal and abnormal exams. Hand motor functional mapping was used as a reference.
RESULTS: In normal hemispheres (n = 50), the mean CR was significantly lower on DIR (0.44) vs T1-MPRAGE (0.63, p < 0.001). Reduced gray-white matter contrast was categorized as "definitely present" more frequently on DIR than T1-MPRAGE by reviewers in both normal (n = 50; reviewer 1 DIR 88% and MPRAGE 68%, p = 0.02; reviewer 2 DIR 86% and T1-MPRAGE 64%; p=0.01) and abnormal hemispheres (n = 50; reviewer 1 DIR 80% and T1-MPRAGE 38%, p < 0.001; reviewer 2 DIR 74% and T1-MPRAGE 46%, p = 0.005).
CONCLUSION: Reduced gray-white matter contrast of the motor cortex is more pronounced on DIR compared to T1-MPRAGE on quantitative and qualitative assessments of normal MRI exams. In abnormal cases, reviewers more definitively identified the motor cortex on DIR. In cases with distorted brain anatomy, DIR may be a useful adjunct sequence to localize the motor cortex.
引用
- Joshi H, Hoch MJ, Braileanu M, et al. Reduced gray-white matter contrast localizes the motor cortex on double inversion recovery (DIR) 3T MRI. Neuroradiology. 2021. PMID: 33415349. doi:10.1007/s00234-020-02631-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。