基于ASL的血管选择性4D MRA在颅内外搭桥术后疗效评估中可能优于3D TOF MRA:一项前瞻性研究
前瞻性纳入45例颅内外血运重建术后患者,以DSA为参考,比较基于超选择性伪连续动脉自旋标记的4D-sPACK与3D TOF MRA评估桥血管通畅性及来自颈外动脉的颅内侧支。4D-sPACK显示吻合口的敏感度高于3D TOF MRA(97.73% vs 79.55%),颅内侧支评分亦更高(3.22±1.15 vs 1.80±0.67,p<0.001),与DSA一致性高。
要点
- 4D-sPACK显示吻合口的敏感度为97.73%,高于3D TOF MRA的79.55%。
- 4D-sPACK颅内侧支评分3.22±1.15,高于3D TOF MRA的1.80±0.67(p<0.001)。
- 4D-sPACK图像质量良好者47/50半球(94.0%),桥血管通畅性观察者间一致性几乎完美(κ=0.912)。
关键影像表现/征象
- 4D-sPACK图像质量采用4分法评估,47/50半球(94.0%)为良好。
- 4D-sPACK显示吻合口的敏感度为97.73%,3D TOF MRA为79.55%。
- 4D-sPACK颅内侧支评分3.22±1.15,3D TOF MRA为1.80±0.67,两者差异有统计学意义(p<0.001)。
诊断标准与关键数值
- 4D-sPACK图像质量采用4分法评估,依据是否影响颅内侧支的诊断。
- 颅内侧支评估采用另一4分法,依据显示的血管数目。
- 颅内侧支评估观察者间一致性:4D-sPACK κ=0.788,3D TOF MRA κ=0.800。
- 桥血管通畅性观察者间一致性:4D-sPACK κ=0.912,3D TOF MRA κ=0.816,DSA κ=0.811。
临床应用与阅片要点
- 4D-sPACK为无对比剂增强的动态MRA方法,用于颅内血管显示。
- 4D-sPACK对吻合口闭塞诊断的特异度高于3D TOF MRA。
- 搭桥术后患者颅内侧支显示,4D-sPACK优于3D TOF MRA。
局限性
- 原文称本研究为先导研究(pilot study)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare bypass patency and intracranial collaterals from the external carotid artery (ECA) by four-dimensional MR angiography (MRA) based on super-selective pseudo-continuous arterial spin labeling (pCASL) combined with the keyhole and view-sharing techniques (4D-sPACK) versus three-dimensional time-of-flight (3D TOF) MRA in patients with extra-intracranial revascularization.
METHODS: The MR data of 45 patients administered bypass surgery were collected. The image quality of 4D-sPACK was evaluated using a 4-point grading system according to whether the diagnosis of intracranial collaterals was affected. Anastomosis patency and intracranial collateral visualization from ECA were assessed by two radiologists on 4D-sPACK and 3D TOF MRA, with digital subtraction angiography (DSA) findings as reference. Intracranial collateral assessment employed another 4-point grading system according to the number of vessels shown. Interobserver agreement was assessed with the weighted kappa statistic.
RESULTS: Fifty hemispheres in 43 patients were included. The image quality of 4D-sPACK was good in 47 (47/50, 94.0%) hemispheres. 4D-sPACK had a higher sensitivity than 3D TOF MRA (97.73% vs 79.55%) for visualizing anastomoses. There were significant differences between 4D-sPACK (scores, 3.22 ± 1.15) and 3D TOF MRA (scores, 1.80 ± 0.67) in the visualization of intracranial collaterals from ECA (p < 0.001). The interobserver agreement was substantial for intracranial collateral assessment (κ4D-sPACK = 0.788; κ3D TOF MRA = 0.800) and almost perfect for bypass patency (κ4D-sPACK = 0.912; κ3D TOF MRA = 0.816; κDSA = 0.811).
CONCLUSION: This pilot study shows that, 4D-sPACK has a better performance than 3D TOF MRA in treatment evaluation of patients after bypass surgery, and has high consistency with DSA.
KEY POINTS: • 4D-sPACK is a non-contrast-enhanced dynamic MRA method for the visualization of intracranial vessels. • 4D-sPACK has higher specificity for the diagnosis of anastomosis occlusion. • 4D-sPACK is better than 3D TOF MRA in the visualization of intracranial collaterals in patients after bypass surgery.
引用
- Wang M, Yang Y, Wang Y, et al. Vessel-selective 4D MRA based on ASL might potentially show better performance than 3D TOF MRA for treatment evaluation in patients with intra-extracranial bypass surgery: a prospective study. Eur Radiol. 2021. PMID: 33386981. doi:10.1007/s00330-020-07503-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。