文献速递神经儿科影像MR

多次给予钆喷酸葡胺对儿童脑磁共振T1加权信号影响的回顾性队列评估

A retrospective cohort evaluation of the effect of multiple administrations of gadopentetate dimeglumine on brain magnetic resonance imaging T1-weighted signal.
PubMed 文献 · Pediatr Radiol · 2021-01-05

回顾性评估50例接受超过5次钆喷酸葡胺的儿童脑MRI,发现随对比剂次数增加,苍白球、齿状核和丘脑枕T1信号显著升高;MRI序列类型和扫描仪厂商显著影响信号比值,且信号变化斜率存在个体差异。

要点

  • 多次钆喷酸葡胺后,儿童脑齿状核、苍白球和丘脑枕T1信号随给药次数增加而显著升高。
  • MRI序列类型(快速自旋回波或梯度回波)和扫描仪厂商显著影响部分脑区信号强度比值。
  • 患者性别、年龄和场强与信号强度比值变化无关。

关键影像表现/征象

  • 随对比剂给药次数增加,苍白球、齿状核和丘脑枕T1信号显著升高。
  • 患者性别、年龄和MRI场强与信号强度比值变化无关。
  • MRI序列类型和厂商显著影响部分测量的信号强度比值。
  • 多个脑区的信号强度比值斜率在患者之间存在显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Gadolinium deposition occurs following repeated administration of gadolinium-based contrast media. However, few studies have evaluated factors that lead to increased detection of deposition or the individual differences among patients.

OBJECTIVE: To measure the effect of repeated dosages of gadopentetate dimeglumine on pediatric brains and to determine the factors that influence signal intensity changes.

MATERIALS AND METHODS: A retrospective study evaluated magnetic resonance imaging (MRI) in patients <18 years of age who received >5 doses of gadopentetate dimeglumine. Regions of interest were placed in 30 locations in the brain on axial precontrast T1 images. Signal intensity ratios were evaluated throughout the brain. The effect of increasing gadopentetate dimeglumine exposure on signal intensity ratios was assessed using linear mixed models adjusted for gender, age, imaging sequence type (fast spin echo or gradient echo), MRI manufacturer (General Electric, Philips or Siemens), and field strength (1.5 tesla [T] or 3 T). Finally, the variance of the random slope in the linear mixed models was tested to determine if there were differences in the rate of signal intensity ratio change among individuals.

RESULTS: Fifty patients (M:F=25:25; mean age at first imaging: 6.4 years) with a mean of 21.5 gadopentetate dimeglumine administrations (range: 6-86) were included. There were significant increases in T1 signal in the globus pallidus, dentate nucleus and pulvinar with an increasing number of contrast administrations. Patient gender, age, and MRI field strength were not associated with changing signal intensity ratios. However, MRI sequence type and vendor significantly impacted some measured signal intensity ratios. Finally, significant differences in the slopes of the ratios were present among patients for multiple locations.

CONCLUSION: Repeated administration of gadopentetate dimeglumine is associated with T1 hyperintense signal in the dentate nucleus, globus pallidus and pulvinar. Detection is significantly affected by MRI sequence type and scanner vendor. Even when accounting for these differences, there are individual differences in the slope of signal intensity change suggesting a patient-level effect influences gadolinium deposition.

来源:Pediatr Radiol,查看原文。版权归原作者所有。