文献速递神经CT

组织残余函数达峰时间可提高CT血管成像检测远端血管闭塞的诊断效能

Time-to-Maximum of the Tissue Residue Function Improves Diagnostic Performance for Detecting Distal Vessel Occlusions on CT Angiography.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-01-01

本回顾性研究纳入70例远端动脉闭塞患者和70例随机对照,由4名不同经验阅片者分别在有/无CT灌注(CTP)衍生的组织残余函数达峰时间(Tmax)图条件下独立判读CT血管成像(CTA)。使用Tmax图后平均敏感度从70.7%升至90.4%,4名阅片者诊断准确率均显著提高(P<.001),诊断信心和判读速度也显著提升。

要点

  • 联合CTP衍生的Tmax图可将CTA检测远端动脉闭塞的平均敏感度从70.7%提升至90.4%。
  • 4名不同经验阅片者诊断准确率均显著改善,AUC分别增加0.186、0.136、0.114和0.121(P<.001)。
  • 使用Tmax图后诊断信心和判读速度均显著提高,对经验丰富与经验不足阅片者均有帮助。

核心结论

  • 使用CTP衍生的组织残余函数Tmax图后,检测远端动脉闭塞的所有评估诊断效能指标均改善,鼓励用其辅助经验丰富和经验不足的阅片者判读CTA。
  • 这些发现显示将CTP纳入急性卒中影像方案具有额外诊断价值。

研究设计与样本

  • 回顾性研究,纳入70例连续远端动脉闭塞患者和70例随机选择的对照,均因疑似急性缺血性卒中接受包含CTA和CTP的多模态CT检查。
  • 4名不同经验水平的阅片者独立判读CTA,分2次独立判读,分别在有和无组织残余函数Tmax图的条件下进行,记录闭塞有无、诊断信心和判读时间。
  • 采用受试者工作特征分析评估检测远端闭塞的准确率,比较曲线下面积以判断使用Tmax后准确率是否提高;诊断信心和判读时间变化采用Wilcoxon符号秩检验评估。

诊断标准与关键数值

  • 使用Tmax图后,检测闭塞的平均敏感度从70.7%升至90.4%。
  • 4名阅片者诊断准确率显著改善(P<.001),受试者工作特征曲线下面积分别增加0.186、0.136、0.114和0.121。

临床应用与阅片要点

  • 作者认为,使用组织残余函数Tmax图辅助判读CTA可提高远端动脉闭塞的检出,对经验丰富和经验不足的阅片者均有帮助。
  • 作者指出,这些发现显示将CTP纳入急性卒中影像方案具有额外诊断价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Detecting intracranial distal arterial occlusions on CTA is challenging but increasingly relevant to clinical decision-making. Our purpose was to determine whether the use of CTP-derived time-to-maximum of the tissue residue function maps improves diagnostic performance for detecting these occlusions.

MATERIALS AND METHODS: Seventy consecutive patients with a distal arterial occlusion and 70 randomly selected controls who underwent multimodal CT with CTA and CTP for a suspected acute ischemic stroke were included in this retrospective study. Four readers with different levels of experience independently read the CTAs in 2 separate sessions, with and without time-to-maximum of the tissue residue function maps, recording the presence or absence of an occlusion, diagnostic confidence, and interpretation time. Accuracy for detecting distal occlusions was assessed using receiver operating characteristic analysis, and areas under curves were compared to assess whether accuracy improved with use of time-to-maximum of the tissue residue function. Changes in diagnostic confidence and interpretation time were assessed using the Wilcoxon signed rank test.

RESULTS: Mean sensitivity for detecting occlusions on CTA increased from 70.7% to 90.4% with use of time-to-maximum of the tissue residue function maps. Diagnostic accuracy improved significantly for the 4 readers (P < .001), with areas under the receiver operating characteristic curves increasing by 0.186, 0.136, 0.114, and 0.121, respectively. Diagnostic confidence and speed also significantly increased.

CONCLUSIONS: All assessed metrics of diagnostic performance for detecting distal arterial occlusions improved with the use of time-to-maximum of the tissue residue function maps, encouraging their use to aid in interpretation of CTA by both experienced and inexperienced readers. These findings show the added diagnostic value of including CTP in the acute stroke imaging protocol.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Amukotuwa SA, Wu A, Zhou K, et al. Time-to-Maximum of the Tissue Residue Function Improves Diagnostic Performance for Detecting Distal Vessel Occlusions on CT Angiography. AJNR Am J Neuroradiol. 2021. PMID: 33431503. doi:10.3174/ajnr.A6891