定量磁敏感加权成像可能准确判定卒中亚低温灌注与半暗带缺氧
研究纳入85例发病12小时内急性缺血性卒中患者,用磁敏感加权成像与定量图谱评估不对称突出皮层静脉,以PWI-DWI不匹配为参考,比较SWIvolume-DWI与SWIASPECTS-DWI不匹配的诊断效能;前者敏感度、阴性预测值和准确率均更高,且与PWI-DWI不匹配及Tmax>6s体积相关性良好。
要点
- SWIvolume-DWI不匹配的敏感度100%、阴性预测值100%、准确率97.7%,均高于SWIASPECTS-DWI不匹配。
- SWIvolume-DWI与PWI-DWI不匹配呈正相关(r=0.691,p<0.01),与Tmax>6s体积呈正相关(r=0.786,p<0.001)。
- SWIvolume-DWI不匹配与NIHSS呈负相关(r=-0.360,p=0.022),SWIASPECTS-DWI不匹配与NIHSS亦呈负相关(r=-0.499,p=0.001)。
关键影像表现/征象
- SWIM上可见不对称突出皮层静脉(APCV),并据此定量计算SWI-volume和半定量计算SWI-ASPECTS。
- SWIvolume-DWI不匹配与PWI-DWI不匹配呈正相关(r=0.691,p<0.01)。
- SWI-volume与Tmax>6s体积呈正相关(r=0.786,p<0.001)。
诊断标准与关键数值
- 以PWI-DWI不匹配为参考,SWIvolume-DWI不匹配的敏感度100%、阴性预测值100%、准确率97.7%。
- 以PWI-DWI不匹配为参考,SWIASPECTS-DWI不匹配的敏感度53.7%、阴性预测值9.5%、准确率54.5%。
- SWIvolume-DWI不匹配与NIHSS呈负相关(r=-0.360,p=0.022)。
- SWIASPECTS-DWI不匹配与NIHSS呈负相关(r=-0.499,p=0.001)。
临床应用与阅片要点
- 作者认为,用SWIM定量APCV体积可准确判定低灌注区,并可靠反映半暗带缺氧。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To quantitatively evaluate the volume of the ischemic penumbra using susceptibility-weighted imaging and mapping (SWIM) of asymmetrical prominent cortical veins (APCVs) in patients with acute ischemic stroke.
METHODS: Eighty-five eligible patients with acute ischemic stroke on admission within 12 h from symptom onset were studied. The APCVs on SWIM were quantitatively (SWI-volume) and semi-quantitatively (SWI-Alberta Stroke Program Early CT Score, SWI-ASPECTS) evaluated to calculate mismatch. To assess the diagnostic efficacy of APCVs on SWIM, comparative analyses were performed between SWIvolume-DWI mismatch and SWIASPECTS-DWI mismatch, using PWI-DWI mismatch as a reference. Correlations were calculated between the mismatches, as well as between SWI-volume and time-to-maximum (Tmax) > 6 s volume. Additionally, each of these mismatches was correlated with the National Institute of Health Stroke Scale (NIHSS).
RESULTS: The sensitivity, negative predictive value, and accuracy of SWIvolume-DWI mismatch were demonstrably higher than SWIASPECTS-DWI mismatch (100% vs. 53.7%, 100% vs. 9.5%, 97.7% vs. 54.5%, respectively). A significant positive correlation was found between SWIvolume-DWI and PWI-DWI mismatch (r = 0.691, p < 0.01), as well as between SWI-volume and Tmax > 6 s volume (r = 0.786, p < 0.001). A significant negative correlation was found between SWIvolume-DWI mismatch and NIHSS (r = - 0.360, p = 0.022), as well as between SWIASPECTS-DWI mismatch and NIHSS (r = - 0.499, p = 0.001).
CONCLUSIONS: SWIvolume-DWI mismatch had higher diagnostic efficacy than SWIASPECTS-DWI mismatch in defining the ischemic penumbra and showed good consistency with PWI-DWI mismatch in acute ischemic stroke. Quantitation of APCVs using SWIM provided an accurate method for determining hypoperfusion and provided a reliable method to reflect the hypoxia of penumbra.
KEY POINTS: • SWIvolume-DWI mismatch has higher diagnostic efficacy than SWIASPECTS-DWI mismatch in defining the ischemic penumbra. • SWIvolume-DWI mismatch shows good consistency with PWI-DWI mismatch in managing penumbra in acute ischemic stroke. • Quantitation of APCV volume using SWIM provided an accurate method for determining the hypoperfusion area and provided a reliable method to reflect the hypoxia of penumbra.
引用
- Lu X, Meng L, Zhou Y, et al. Quantitative susceptibility-weighted imaging may be an accurate method for determining stroke hypoperfusion and hypoxia of penumbra. Eur Radiol. 2021. PMID: 33512568. doi:10.1007/s00330-020-07485-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。