急性卒中前循环CT血管造影血栓高性能自动检测:多阅片者比较
本回顾性分析纳入217例(平均年龄64岁±16,116名男性,109例LVO阳性)脑血管CTA数据,评估自动平台检测颅内ICA或MCA M1段LVO的性能。
要点
- 自动平台检测颅内ICA或MCA M1段LVO的敏感度96%、特异度98%,AUC达99%。
- 各年龄、性别、位置和厂商亚组的敏感度与特异度估计值均超过90%。
- 平均处理与通知时间为3分18秒,满足预设的低于3.5分钟通知时间下的性能阈值。
核心结论
- 结果证实快速自动高性能检测颅内ICA和MCA M1段闭塞的可行性。
研究设计与样本
- 回顾性分析,数据来自近期脑血管试验(CRISP和DASH)的CTA数据,并补充来自全球11个站点的本地数据库以平衡LVO阳性与阴性检查的人口学和技术变量,共217例受试者(平均年龄64岁±16,116名男性,109例LVO阳性)。
诊断标准与关键数值
- 以颅内ICA或MCA M1段LVO为检测目标,由两家不同机构的两位神经放射学家独立阅片判定,对临床变量和结局盲法,意见不一致时由第三家机构的盲法三级阅片者裁定。
- 预设性能阈值为敏感度和特异度95%CI下限均≥0.8,且平均通知时间<3.5分钟,实际结果超过该阈值。
- 年龄、性别、位置和厂商亚组的敏感度与特异度估计值均超过90%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Identification of large vessel occlusion (LVO) is critical to the management of acute ischemic stroke and prerequisite to endovascular therapy in recent trials. Increasing volumes and data complexity compel the development of fast, reliable, and automated tools for LVO detection to facilitate acute imaging triage. Purpose To investigate the performance of an anterior circulation LVO detection platform in a large mixed sample of individuals with and without LVO at cerebrovascular CT angiography (CTA). Materials and Methods In this retrospective analysis, CTA data from recent cerebrovascular trials (CRISP [ClinicalTrials.gov NCT01622517] and DASH) were enriched with local repositories from 11 worldwide sites to balance demographic and technical variables in LVO-positive and LVO-negative examinations. CTA findings were reviewed independently by two neuroradiologists from different institutions for intracranial internal carotid artery (ICA) or middle cerebral artery (MCA) M1 LVO; these observers were blinded to all clinical variables and outcomes. An automated analysis platform was developed and tested for prediction of LVO presence and location relative to reader consensus. Discordance between readers with respect to LVO presence or location was adjudicated by a blinded tertiary reader at a third institution. Sensitivity, specificity, and receiver operating characteristics were assessed by an independent statistician, and subgroup analyses were conducted. Prespecified performance thresholds were set at a lower bound of the 95% CI of sensitivity and specificity of 0.8 or greater at mean times to notification of less than 3.5 minutes. Results A total of 217 study participants (mean age, 64 years ± 16 [standard deviation]; 116 men; 109 with positive findings of LVO) were evaluated. Prespecified performance thresholds were exceeded (sensitivity, 105 of 109 [96%; 95% CI: 91, 99]; specificity, 106 of 108 [98%; 95% CI: 94, 100]). Sensitivity and specificity estimates across age, sex, location, and vendor subgroups exceeded 90%. The area under the receiver operating characteristic curve was 99% (95% CI: 97, 100). Mean processing and notification time was 3 minutes 18 seconds. Conclusion The results confirm the feasibility of fast automated high-performance detection of intracranial internal carotid artery and middle cerebral artery M1 occlusions. © RSNA, 2021 See also the editorial by Kloska in this issue.
引用
- Dehkharghani S, Lansberg M, Venkatsubramanian C, et al. High-Performance Automated Anterior Circulation CT Angiographic Clot Detection in Acute Stroke: A Multireader Comparison. Radiology. 2021. PMID: 33434110. doi:10.1148/radiol.2021202734
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。