文献速递神经MR

联合磁共振成像与脑电图识别帕金森病伴轻度认知障碍

Identifying Parkinson's disease with mild cognitive impairment by using combined MR imaging and electroencephalogram.
PubMed 文献 · Eur Radiol · 2021-01-03

本研究回顾性分析36例帕金森病伴轻度认知障碍(PD-MCI)与35例帕金森病认知正常(PD-NC)患者,提取定量脑电图(qEEG)功率谱特征与基于表面形态学(SBM)的皮层结构MR特征,建立支持向量机(SVM)模型识别PD-MCI。基于qEEG与结构MR联合特征的SVM模型在测试集中准确率0.80、敏感度0.78、特异度0.83、AUC 0.77,高于单独特征模型;C3导联theta波对分类影响最大。

要点

  • 联合qEEG与皮层结构MR特征的SVM模型识别PD-MCI测试集准确率0.80、敏感度0.78、特异度0.83、AUC 0.77。
  • PD-MCI与PD-NC在5个导联的qEEG波及7个皮层区域结构MR特征上差异有统计学意义。
  • 按MIV算法,C3导联theta波是对SVM分类影响最大的qEEG特征。

关键影像表现/征象

  • 与PD-NC相比,PD-MCI在5个导联的qEEG波及7个皮层区域结构MR特征上差异有统计学意义。
  • 基于qEEG与结构MR联合特征的SVM模型训练集准确率0.80,测试集准确率0.80(敏感度0.78,特异度0.83,AUC 0.77),高于单独特征所建模型。
  • 按MIV算法,C3导联theta波对SVM分类模型影响最大。

诊断标准与关键数值

  • SVM模型基于qEEG与结构MR联合特征识别PD-MCI:训练集准确率0.80;测试集准确率0.80、敏感度0.78、特异度0.83、AUC 0.77。

临床应用与阅片要点

  • 作者认为「复合标记物」可能有助于通过机器学习对PD-MCI进行个体化诊断。
  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To analyse the changes of quantitative electroencephalogram (qEEG) and cortex structural magnetic resonance (MR) imaging in Parkinson's disease with mild cognitive impairment (PD-MCI) and to explore the "composite marker"-based machine learning model in identifying PD-MCI.

METHODS: Retrospective analysis of patients with PD identified 36 PD-MCI and 35 PD with normal cognition (PD-NC). QEEG features of power spectrum and structural MR features of cortex based on surface-based morphometry (SBM) were extracted. Support vector machine (SVM) was established using combined features of structural MR and qEEG to identify PD-MCI. Feature importance evaluation algorithm of mean impact value (MIV) was established to sort the vital characteristics of qEEG and structural MR.

RESULTS: Compared with PD-NC, PD-MCI showed a statistically significant difference in 5 leads and waves of qEEG and 7 cortical region features of structural MR. The SVM model based on these qEEG and structural MR features yielded an accuracy of 0.80 in the training set and had a high prediction accuracy of 0.80 in the test set (sensitivity was 0.78, specificity was 0.83, area under the receiver operating characteristic curve was 0.77), which was higher than the model built by the feature separately. QEEG features of theta wave in C3 had a marked impact on the model for classification according to the MIV algorithm.

CONCLUSIONS: PD-MCI is characterized by widespread structural and EEG abnormality. "Composite markers" could be valuable for the individualized diagnosis of PD-MCI by machine learning.

KEY POINTS: • Explore the brain abnormalities in Parkinson's disease with mild cognitive impairment by using the quantitative electroencephalogram and cortex structural MR simultaneously. • Multimodal features based support vector machine for identifying Parkinson's disease with mild cognitive impairment has an acceptable performance. • Theta wave in C3 is the most influential feature of qEEG and cortex structure MR imaging in identifying Parkinson's disease with mild cognitive impairment using support vector machine.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang J, Gao Y, He X, et al. Identifying Parkinson's disease with mild cognitive impairment by using combined MR imaging and electroencephalogram. Eur Radiol. 2021. PMID: 33389038. doi:10.1007/s00330-020-07575-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。