宫外环境支持胎羊发育中的对比增强脑超声灌注指标与血流动力学参数的相关性
研究将9只胎羊转移至宫外支持装置,经脐静脉注射超声造影剂后行脑灌注分析,共完成86次超声检查、72次可定量。结果显示时间依赖型灌注指标与心率、平均动脉压等血流动力学参数均无显著相关(均P≥.05),而曲线下面积指标与氧输送和平均血流量相关(均P≤.01)。作者认为时间依赖型指标可能反映脑血流变化,曲线下面积指标可提供标准监测之外的额外信息。
要点
- 时间依赖型脑超声灌注指标与心率、平均动脉压无显著相关(均P≥.05)。
- 曲线下面积型灌注指标与氧输送、平均血流量相关(均P≤.01)。
- 生理范围的心率与平均动脉压与任何灌注指标均无显著相关(均P≥.05)。
关键影像表现/征象
- 共完成86次超声检查,其中72次可定量分析。
- 时间依赖型灌注指标与所有血流动力学参数均无显著相关(均P≥.05)。
- 曲线下面积型灌注指标与氧输送和平均血流量相关(均P≤.01)。
- 生理范围的心率与平均动脉压与任何灌注指标均无显著相关(均P≥.05)。
局限性
- 原文在结论中使用「are thought to reflect」和「suggesting」等限定措辞,提示相关推断尚需进一步验证。
- 原文在结论中称「these findings enhance the applicability of this technology」,但未报告样本量小、单中心等具体局限的量化描述。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Contrast-enhanced ultrasound (CEUS) can provide quantitative perfusion metrics and may be useful to detect cerebral pathology in neonates and premature infants, particularly in extrauterine environments. The effect of hemodynamics on cerebral perfusion metrics is unknown, which limits the clinical application of this technology. We aimed to determine associations between systemic hemodynamics and concurrently measured brain perfusion parameters in an animal model of extrauterine support.
METHODS: Nine fetal lambs were transferred to an extrauterine support device. Lumason® ultrasound contrast (0.1-0.3 ml) was administered via the umbilical vein and 90-second cine clips were obtained. Time-intensity-curves (TICs) were generated and time-dependent and area-under-curve (AUC) parameters were derived. Associations between brain perfusion metrics and hemodynamics including heart rate (HR) and mean arterial pressure (MAP) were evaluated by multilevel linear mixed-effects models.
RESULTS: Eighty-six ultrasound examinations were performed and 72 examinations were quantifiable. Time-dependent measurements were independent of all hemodynamic parameters (all p ≥.05). Oxygen delivery and mean blood flow were correlated with AUC measurements (all p ≤.01). Physiologic HR and MAP were not correlated with any measurements (all p ≥.05).
CONCLUSION: Detected aberrations in time-dependent CEUS measurements are not correlated with hemodynamic parameters and are thought to reflect the changes in cerebral blood flow, thus providing a promising tool for evaluation of brain perfusion. CEUS brain perfusion parameters are not correlated with physiologic HR and MAP, but AUC-dependent measurements are correlated with oxygen delivery and blood flow, suggesting that CEUS offers additional value over standard monitoring. Overall, these findings enhance the applicability of this technology.