基于深度学习的检测软件提高肋骨骨折检测准确性和阅读效率:一项临床评估

Improving rib fracture detection accuracy and reading efficiency with deep learning-based detection software: a clinical evaluation.
PubMed 文献 · Br J Radiol · 2020-12-17

纳入198例钝性胸部外伤薄层CT患者,由两名放射科医生在无辅助、深度学习同步辅助和深度学习第二读者三种模式下阅片。深度学习辅助使两名医生敏感性从82.8%和83.9%分别提高至88.9%和88.7%以上,阅读时间减少36%和34%。

要点

  • 深度学习同步辅助可提高肋骨骨折CT检测敏感性,R1从82.8%升至88.9%,R2从83.9%升至88.7%。
  • 深度学习辅助使阅读时间分别减少36%(R1)和34%(R2)。
  • 深度学习可整合入放射科工作流程以提高肋骨骨折CT检测的准确性和阅读效率。

核心结论

  • 使用深度学习作为同步读者可提高肋骨骨折的检测准确性和阅读效率。

研究设计与样本

  • 纳入198例钝性胸部外伤行薄层CT的患者,由两名放射科医生(R1、R2)分三次阅片:S1无辅助、S2深度学习同步辅助、S3深度学习作为第二读者。
  • 肋骨骨折参考标准由专家小组建立,计算并比较S1、S2、S3的敏感性和每扫描假阳性数。

诊断标准与关键数值

  • 参考标准在102例患者的713根肋骨上确定865处骨折。
  • 敏感性:S1为R1 82.8%、R2 83.9%;S2为R1 88.9%、R2 88.7%;S3为R1 88.7%、R2 88.8%。
  • S2和S3敏感性均显著高于S1(所有p < 0.05),S2与S3之间无显著差异(均p > 0.9)。
  • 每扫描假阳性数:R1各次间无差异(p = 0.24);R2的S2和S3均低于S1(均p < 0.05)。

临床应用与阅片要点

  • 深度学习可作为同步读者整合入放射科工作流程,以提高肋骨骨折CT检测的准确性和阅读效率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the impact of deep learning (DL) on radiologists' detection accuracy and reading efficiency of rib fractures on CT.

METHODS: Blunt chest trauma patients (n = 198) undergoing thin-slice CT were enrolled. Images were read by two radiologists (R1, R2) in three sessions: S1, unassisted reading; S2, assisted by DL as the concurrent reader; S3, DL as the second reader. The fractures detected by the readers and total reading time were documented. The reference standard for rib fractures was established by an expert panel. The sensitivity and false-positives per scan were calculated and compared among S1, S2, and S3.

RESULTS: The reference standard identified 865 fractures on 713 ribs (102 patients) The sensitivity of S1, S2, and S3 was 82.8, 88.9, and 88.7% for R1, and 83.9, 88.7, and 88.8% for R2, respectively. The sensitivity of S2 and S3 was significantly higher compared to S1 for both readers (all p < 0.05). The sensitivity between S2 and S3 did not differ significantly (both p > 0.9). The false-positive per scan had no difference between sessions for R1 (p = 0.24) but was lower for S2 and S3 than S1 for R2 (both p < 0.05). Reading time decreased by 36% (R1) and 34% (R2) in S2 compared to S1.

CONCLUSIONS: Using DL as a concurrent reader can improve the detection accuracy and reading efficiency for rib fracture.

ADVANCES IN KNOWLEDGE: DL can be integrated into the radiology workflow to improve the accuracy and reading efficiency of CT rib fracture detection.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang B, Jia C, Wu R, et al. Improving rib fracture detection accuracy and reading efficiency with deep learning-based detection software: a clinical evaluation. Br J Radiol. 2020. PMID: 33332979. doi:10.1259/bjr.20200870

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。