不同照射角度下颈内动脉多普勒速度测量的变化:一项先导研究
该先导研究在22名无症状志愿者的44条颈内动脉上,于45°、50°、55°和60°四个多普勒照射角度及不同声束偏转条件下测量峰值收缩期流速(PSV)。结果显示PSV随角度变化差异有统计学意义(P < .01),60°时均值、方差最大且相关性最低;作者认为需要一致的超声技术,并建议进一步研究最佳多普勒角度。
要点
- 颈内动脉PSV随多普勒照射角度(45°–60°)变化差异有统计学意义(P < .01),单血管内45°与60°间最大差异达29 cm/s。
- 60°照射时PSV的均值、方差最大且相关性最低,其标准差约为50°时的近两倍(7.9 vs 3.9)。
- 45°与50°之间计算平均速度相关性最佳(中心偏转r(36)=0.92,P < .001;右侧偏转r(40)=0.96,P < .001)。
关键影像表现/征象
- PSV随45°、50°、55°和60°四个照射角度变化差异有统计学意义(P < .01)。
- 单条血管内45°与60°角度之间PSV最大差异为29 cm/s。
- 四个角度的平均差异为14 ± 6 cm/s。
- 相对于所有受试者的计算平均速度,60°时PSV的标准差约为50°时的近两倍(7.9 vs 3.9)。
诊断标准与关键数值
- 所有受试者计算平均速度的最佳相关性见于45°与50°之间:中心偏转数据r(36)=0.92,P < .001;右侧偏转数据r(40)=0.96,P < .001。
临床应用与阅片要点
- 作者认为结果支持需要一致的超声技术,并建议进一步研究速度测量的最佳多普勒角度。
局限性
- 原文结论指出进一步研究最佳多普勒角度是必要的(suggest that further study is warranted)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Doppler velocity measurements are fundamental diagnostic criteria for vascular ultrasound examinations. Insonation angles are kept to 60° or less to minimize error. The purpose of this study was to assess variance of Doppler-detected peak systolic velocity (PSV) measurements in the internal carotid arteries at different angles (45°, 50°, 55°, and 60°) with different beam steering.
METHODS: The PSV was recorded from the right and left internal carotid arteries in 22 asymptomatic volunteers with straight vessels (total of 44 vessels). A standardized approach was used for recording velocities with the Doppler cursor center steered and steered 15° from right to left. An analysis of variance was performed.
RESULTS: The PSV varied significantly with the 4 different angles of insonation (P < .01). The maximum variation between 45° and 60° angles within a single vessel was 29 cm/s. The average variation over the 4 angles was 14 ± 6 cm/s. Relative to the calculated mean velocity for all patients, the standard deviation for the PSV at 60° was nearly twice that recorded at 50° (7.9 versus 3.9). The best correlation of the calculated mean velocity for all patients existed between the angles of 45° and 50° [r(36) = 0.92; P < .001 for center-steered data; and r(40) = 0.96; P < .001 for right-steered data].
CONCLUSIONS: These results indicate a statistically significant difference in the PSV measurements taken at varying Doppler angles. The greatest mean, variance, and lowest correlations all result when using 60°. The findings support the need for consistent ultrasound techniques and suggest that further study is warranted regarding the optimal Doppler angle for velocity measurements.
引用
- Campbell KA, Kupinski AM, Miele FR, et al. Changes in Internal Carotid Artery Doppler Velocity Measurements With Different Angles of Insonation: A Pilot Study. J Ultrasound Med. 2020. PMID: 33274771. doi:10.1002/jum.15579
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。