评估加速三维调制翻转角技术结合压缩感知与扩展回波链序列在膝关节成像中的应用:与常规二维MRI序列的比较
研究纳入68名受试者在3T MRI上比较三维矩阵序列(结合压缩感知)与常规二维质子密度及快速自旋回波序列。结果显示中位采集时间缩短44.5%,图像质量评分一致性高,结构相似指数可接受,信噪比和对比噪声比无显著差异。结论为三维矩阵序列可在不损失图像质量、信噪比和对比噪声比的情况下缩短膝关节MRI采集时间。
要点
- 三维矩阵序列中位采集时间缩短44.5%,图像质量与常规二维序列一致性高。
- 三维矩阵FSE与二维FSE、三维矩阵PD与二维PD的结构相似指数分别为0.994和0.971。
- 信噪比和对比噪声比在三维矩阵与常规二维序列间无显著差异。
关键影像表现/征象
- 三维矩阵FSE与二维FSE、三维矩阵PD与二维PD序列的平均结构相似指数分别为0.994和0.971,属可接受范围。
- 三维矩阵FSE与二维FSE、三维矩阵PD与二维PD序列间信噪比无显著差异,尽管常规二维序列信噪比似乎更高。
- 软骨下骨-半月板、软骨下骨-关节液和半月板-关节液的对比噪声比在三维矩阵序列与常规二维序列间无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To accelerate the acquisition of high-resolution magnetic resonance imaging (MRI) by using the three-dimensional (3D) matrix sequence with compressed sensing and to compare it with conventional two-dimensional (2D) proton-density (PD) and fast spin-echo (FSE) sequences.
MATERIALS AND METHODS: 3D matrix, 2D FSE, and PD sequences were acquired from 68 participants using 3 T magnetic resonance imaging (MRI). Two radiologists scored image quality independently on a four-point scale. The structural similarity index (SSIM), and signal- (SNRs) and contrast-to-noise ratios (CNRs) of different anatomical structures of the knee were assessed and compared between sequences using Wilcoxon signed-rank tests and Cohen's kappa.
RESULTS: The median acquisition time reduction was 44.5%. There was a substantial to perfect agreement for the rating between the 3D matrix FSE and 2D FSE or PD sequences when evaluating cartilage, subchondral bone, and ligaments (κ=0.783-872, p>0.05). The mean SSIM values between the 3D matrix FSE and 2D FSE, and between the 3D matrix PD and 2D PD sequences was 0.994 and 0.971, respectively, which are acceptable. No significant differences were found in SNR between the 3D matrix FSE and 2D FSE, and between the 3D matrix PD and 2D PD sequences, even though the SNR appeared to be higher on routine 2D sequences. The CNR of subchondral bone-meniscus, subchondral bone-joint fluid, and meniscus-joint fluid did not differentiate significantly between the 3D matrix sequence and routine 2D sequences.
CONCLUSIONS: 3D matrix reduced the acquisition time in routine clinical knee MRI without the loss in image quality, SNR, and CNR.
引用
- Li G, Wu D, Xu Z, et al. Evaluation of an accelerated 3D modulated flip-angle technique in refocused imaging with an extended echo-train sequence with compressed sensing for imaging of the knee: comparison with routine 2D MRI sequences. Clin Radiol. 2020. PMID: 33250173. doi:10.1016/j.crad.2020.10.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。