文献速递骨肌CTDR

负重计算机断层扫描与负重平片对中足骨关节炎诊断敏感性的比较评估

Comparative assessment of midfoot osteoarthritis diagnostic sensitivity using weightbearing computed tomography vs weightbearing plain radiography.
PubMed 文献 · Eur J Radiol · 2020-11-21

该回顾性分析纳入302只患足,以负重计算机断层扫描(WBCT)为参考标准,比较负重平片(WBPR)对中足三组关节骨关节炎的诊断效能。WBPR对Chopart关节诊断敏感度72.5%、特异度87.9%,对中央关节敏感度61.5%、特异度96.1%,对跗跖关节敏感度68.4%、特异度92.9%;WBPR对退变严重程度的一贯低估,中足骨关节炎常被漏诊。

要点

  • WBPR对中足骨关节炎诊断敏感度不足(Chopart 72.5%、中央关节61.5%、跗跖关节68.4%),易漏诊。
  • WBPR对中足骨关节炎退变严重程度相对WBCT一致性低估。
  • WBCT有利于中足骨关节炎更早期、更可靠的诊断与分级。

核心结论

  • 本系列中,中足骨关节炎在WBPR上常未被检出。
  • 相对WBPR,WBCT有助于中足骨关节炎更早期、更可靠的诊断与分级。

研究设计与样本

  • 标准化回顾性患者内分析,比较WBPR与WBCT对中足骨关节炎诊断及严重程度分级的差异。
  • 样本为来自内部连续患者数据库的302只患足,采用详细纳入标准。
  • 由肌肉骨骼放射科医师分别判读每只患足的WBCT与WBPR,评估3组中足关节(Chopart、中央、跗跖关节)特定关节是否有骨关节炎直接诊断或骨关节炎征象提及。
  • 以WBCT作为参考标准计算WBPR的敏感度与特异度。

诊断标准与关键数值

  • 以WBCT为参考标准,WBPR诊断Chopart关节骨关节炎的敏感度72.5%、特异度87.9%。
  • 以WBCT为参考标准,WBPR诊断中央关节骨关节炎的敏感度61.5%、特异度96.1%。
  • 以WBCT为参考标准,WBPR诊断跗跖关节骨关节炎的敏感度68.4%、特异度92.9%。
  • WBPR对退变严重程度的判读相对WBCT一致性低估。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Accuracy in diagnosing osteoarthritis in the midfoot using weightbearing plain radiography (WBPR) remains questionable due to the overlapping osseous architecture present, occluding visualization. Weightbearing computed tomography (WBCT), providing clearer bony landmark identification and joint space visualization, can also be used for evaluation. The aim of this project is to perform a standardized retrospective intra-patient analysis identifying the discrepancy of midfoot osteoarthritis diagnosis and osteoarthritis severity grading between WBPR and WBCT.

METHODS AND MATERIALS: A cohort of 302 patient feet was acquired from an internal, consecutive patient database using detailed inclusion criteria. The musculoskeletal radiologist interpretation of the WBCT and WBPR of each specimen was then assessed for any direct diagnosis or mention of osteoarthritic signs in specific articulations of 3 midfoot joint groups (Chopart, "central", and tarsometatarsal). WBPR sensitivity and specificity metrics were calculated with WBCT considered the gold standard for comparison.

RESULTS: From the WBPR radiologist interpretation, we found diagnostic sensitivity of 72.5 % and specificity of 87.9 % for Chopart joints; 61.5 % sensitivity, and 96.1 % specificity for central joints; and 68.4 % sensitivity, and 92.9 % specificity for tarsometatarsal joints. The severity of degenerative changes was also consistently underestimated when interpreted from WBPR relative to WBCT.

CONCLUSIONS: In this series, midfoot osteoarthritis was often undetected on WBPR. WBCT imaging facilitates an earlier, more reliable diagnosis and grading of midfoot osteoarthritis relative to WBPR.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Steadman J, Sripanich Y, Rungprai C, et al. Comparative assessment of midfoot osteoarthritis diagnostic sensitivity using weightbearing computed tomography vs weightbearing plain radiography. Eur J Radiol. 2020. PMID: 33259992. doi:10.1016/j.ejrad.2020.109419

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。