应用能量多普勒、超声剪切波弹性成像与MR信号特征评估肩袖修复愈合的超声-MRI相关性:一项先导研究
这项前瞻性先导研究纳入12例单侧全层冈上肌腱撕裂行肩袖修复的患者,术前及术后3、6个月行MRI和超声检查,测量肌腱-三角肌MR信号强度比(TMR)、能量多普勒血管性评分和剪切波速度(SWV)。结果显示TMR和血管性先升高后降低,术后SWV先降低后升高且与3个月时TMR呈负相关(r=-0.73,p=0.005),能量多普勒示肌腱血管性随时间较对侧对照有统计学显著变化(3个月p=0.009;6个月p=0.036)。作者认为MRI和超声参数的时间关系与肩袖修复后预期愈合阶段平行。
要点
- 肩袖修复术后TMR和能量多普勒血管性评分呈先升高后降低的时间变化。
- 术后SWV先降低后升高,3个月时与TMR呈负相关(r=-0.73,p=0.005)。
- 能量多普勒示肌腱血管性随时间较对侧对照有统计学显著变化(3个月p=0.009;6个月p=0.036)。
关键影像表现/征象
- 肌腱修复处TMR和血管性术后初期升高、随后降低。
- 术后SWV初期降低、后期升高,虽未达统计学显著,但与3个月时TMR呈负相关(r=-0.73,p=0.005)。
- 能量多普勒示肌腱血管性随时间较对侧对照有统计学显著变化(3个月p=0.009;6个月p=0.036)。
- TMR与SWE在6个月时无显著相关性,TMR与能量多普勒在任何时间点均无显著相关性。
局限性
- 原文指出患者队列小。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine whether the healing response in rotator cuff repairs can be quantitatively characterized using a multimodality imaging approach with MR signal intensity, power Doppler and shear wave elastography (SWE).
MATERIALS AND METHODS: Patients scheduled for rotator cuff repair were prospectively enrolled between September 2013 and June 2016. A 12 patient cohort with unilateral, full-thickness, supraspinatus tendon tears underwent MRI and ultrasound both preoperatively and postoperatively (at 3 and 6 months post-surgery). The MR signal intensity ratio of tendon-to-deltoid muscle (TMR), vascularity score by power Doppler (PD) and shear wave velocity (SWV) were measured. Repaired and asymptomatic control shoulders were compared over time and between modalities.
RESULTS: TMR and vascularity of the tendon repair initially increased and then decreased postoperatively. Although not achieving statistical significance, postoperative SWV initially decreased and later increased, which negatively correlated with the TMR at 3 months (r = -0.73, p = 0.005). PD demonstrated a statistically significant change in tendon vascularity over time compared to the contralateral control (p = 0.009 at 3 months; p = 0.036 at 6 months). No significant correlation occurred between TMR and SWE at 6 months, or with PD at any time point.
CONCLUSION: Despite a small patient cohort, this prospective pilot study suggests a temporal relationship of MRI and ultrasound parameters that parallels the expected phases of healing in the repaired rotator cuff.
引用
- Nocera NL, Burke CJ, Gyftopoulos S, et al. Ultrasound-MRI Correlation for Healing of Rotator Cuff Repairs Using Power Doppler, Sonographic Shear Wave Elastography and MR Signal Characteristics: A Pilot Study. J Ultrasound Med. 2020. PMID: 33258512. doi:10.1002/jum.15583
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。