文献速递骨肌介入USCT

疑似关节内软组织肿瘤及肿瘤样病变:影像引导空心针活检的表现

Suspected intra-articular soft-tissue tumours and tumour-like lesions: Performance of image-guided core needle biopsy.
PubMed 文献 · Eur J Radiol · 2020-12-05

回顾性研究纳入2019年1月至2020年5月转诊至骨与软组织肿瘤专科的91例疑似关节内软组织肿瘤患者,行影像引导空心针活检(IGCNB),93.4%(85/91)获得明确组织学结果,其中44例行手术切除,活检与切除病理一致率95.5%(42/44),无近期或远期并发症记录。

要点

  • 疑似关节内软组织肿瘤行IGCNB的明确诊断率为93.4%(85/91)。
  • 活检与手术切除病理一致率为95.5%(42/44)。
  • 本组最常见诊断为腱鞘巨细胞瘤,仅1例恶性病变。

核心结论

  • 对疑似关节内肿瘤或肿瘤样病变行IGCNB是一种高效且安全的技术。

研究设计与样本

  • 回顾性研究,纳入2019年1月至2020年5月共16个月内转诊至骨与软组织肿瘤专科的疑似关节内软组织肿瘤患者。
  • 共91例患者接受IGCNB,其中男性32例(35.2%)、女性59例(64.8%),平均年龄41.4岁(范围3-86岁)。
  • 记录影像引导方式(超声或CT)、针类型、麻醉方式(全身麻醉或局部麻醉)及组织学诊断;对行手术切除者将IGCNB组织学与切除组织学进行对照。

诊断标准与关键数值

  • IGCNB在91例中85例(93.4%)获得明确组织学结果。
  • 44例后续行手术切除,IGCNB与切除组织学一致42例(95.5%)。
  • 76例局灶性病变的平均最大肿瘤径线为36.5 mm(范围18-113 mm)。

临床应用与阅片要点

  • 关节受累分布以膝关节最常见(73例,80.2%),其次为踝关节(12例,13.2%)、髋关节(3例,3.3%)、肩关节(1例,1.1%)、肘关节(1例,1.1%)及腕关节(1例,1.1%)。
  • 活检方式包括超声引导全身麻醉(29例,31.9%)、超声引导局部麻醉(37例,40.7%)、CT引导全身麻醉(23例,25.3%)及CT引导局部麻醉(2例,2.2%)。
  • 本组最常见诊断为腱鞘巨细胞瘤,仅发现1例恶性病变;无近期或远期并发症记录。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the efficacy of image-guided core needle biopsy (IGCNB) in patients presenting with suspected intra-articular soft tissue tumours or tumour-like lesions.

METHODS: Retrospective study of patients referred to a musculoskeletal oncology service between January 2019 and May 2020 with a suspected intra-articular soft tissue tumour over a 16-month period. Data collected included patient age, gender, joint involved and maximal lesion size. Type of image-guidance (ultrasound or computed tomography), type of needle and type of anaesthesia, general anaesthetic (GA) or local anaesthetic (LA), were recorded, as was the histological diagnosis. For patients who proceeded to surgical excision, the IGCNB histology result was correlated with resection histology. Descriptive statistics were used and complications were also noted.

RESULTS: By the termination of data collection 91 patients underwent IGCNB, 32 (35.2 %) males and 59 (64.8 %) females with a mean age of 41.4 years (age range 3-86 years). The joints involved were the knee (n = 73; 80.2 %), ankle (n = 12; 13.2 %), hip (n = 3; 3.3 %), shoulder (n = 1; 1.1 %), elbow (n = 1; 1.1 %) and wrist (n = 1; 1.1 %). Biopsy types were as follows: US-guided GA (n = 29; 31.9 %), US-guided LA (n = 37; 40.7 %), CT-guided GA, (n = 23; 25.3 %), CT-guided LA (n = 2; 2.2 %). Mean maximal tumour dimension for 76 focal lesions was 36.5 mm (range 18-113 mm). IGCNB yielded a definitive histological result in 85 of 91 cases (93.4 %), 44 of whom went on to surgical resection. Concordance between IGCNB and resection histology was achieved in 42 of 44 cases (95.5 %). The commonest diagnosis was tenosynovial giant cell tumour, with only a single malignant lesion identified. There were no recorded immediate or delayed complications.

CONCLUSIONS: IGCNB of suspected intra-articular tumours or tumour-like lesions is a highly effective and safe technique.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Junaid SE, Bilal S, Saifuddin A, et al. Suspected intra-articular soft-tissue tumours and tumour-like lesions: Performance of image-guided core needle biopsy. Eur J Radiol. 2020. PMID: 33348281. doi:10.1016/j.ejrad.2020.109469

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。