文献速递甲状腺与浅表头颈技术与安全US

超声甲状腺结节计算机辅助诊断系统:基于甲状腺影像报告和数据系统分类与二分结果的诊断性能

Computer-Aided Diagnostic System for Thyroid Nodules on Ultrasonography: Diagnostic Performance Based on the Thyroid Imaging Reporting and Data System Classification and Dichotomous Outcomes.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-12-24

该研究纳入372例连续患者共454个甲状腺结节,比较商用计算机辅助诊断系统与放射科医师基于K-TIRADS、ATA-TIRADS分类及二分结果(可能良性或可能恶性)诊断甲状腺癌的性能。计算机辅助诊断系统敏感度与医师无显著差异,但特异度和准确度显著低于医师;二分结果可降低不必要的细针穿刺率。

要点

  • 计算机辅助诊断系统在二分结果格式下准确度为81.7%,高于K-TIRADS的49.6%和ATA-TIRADS的53.5%。
  • 计算机辅助诊断系统敏感度与放射科医师无显著差异,但特异度和准确度显著低于医师(均P < .001)。
  • 二分结果评估可降低不必要的细针穿刺率,尤其是放射科医师操作时。

诊断标准与关键数值

  • 计算机辅助诊断系统诊断甲状腺癌的敏感度、特异度、阳性预测值、阴性预测值和准确度:K-TIRADS分别为97.6%、21.6%、42.0%、93.9%、49.6%。
  • ATA-TIRADS分别为94.6%、29.6%、43.9%、90.4%、53.5%。
  • 二分结果分别为81.4%、81.9%、72.3%、88.3%、81.7%。
  • 计算机辅助诊断系统敏感度与放射科医师无显著差异(均P > .05);特异度和准确度显著低于放射科医师(均P < .001)。
  • K-TIRADS和ATA-TIRADS分类描述的观察者间一致性为一般至中等,二分结果为基本一致。

临床应用与阅片要点

  • 临床医生应了解使用计算机辅助诊断系统诊断甲状腺癌的优缺点。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Artificial intelligence-based computer-aided diagnostic systems have been introduced for thyroid cancer diagnosis. Our aim was to compare the diagnostic performance of a commercially available computer-aided diagnostic system and radiologist-based assessment for the detection of thyroid cancer based on the Thyroid Imaging Reporting and Data Systems (TIRADS) and dichotomous outcomes.

MATERIALS AND METHODS: In total, 372 consecutive patients with 454 thyroid nodules were enrolled. The computer-aided diagnostic system was set up to render a possible diagnosis in 2 formats, the Korean Society of Thyroid Radiology (K)-TIRADS and the American Thyroid Association (ATA)-TIRADS-classifications, and dichotomous outcomes (possibly benign or possibly malignant).

RESULTS: The diagnostic sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the computer-aided diagnostic system for thyroid cancer were, respectively, 97.6%, 21.6%, 42.0%, 93.9%, and 49.6% for K-TIRADS; 94.6%, 29.6%, 43.9%, 90.4%, and 53.5% for ATA-TIRADS; and 81.4%, 81.9%, 72.3%, 88.3%, and 81.7% for dichotomous outcomes. The sensitivities of the computer-aided diagnostic system did not differ significantly from those of the radiologist (all P > .05); the specificities and accuracies were significantly lower than those of the radiologist (all P < .001). Unnecessary fine-needle aspiration rates were lower for the dichotomous outcome characterizations, particularly for those performed by the radiologist. The interobserver agreement for the description of K-TIRADS and ATA-TIRADS classifications was fair-to-moderate, but the dichotomous outcomes were in substantial agreement.

CONCLUSIONS: The diagnostic performance of the computer-aided diagnostic system varies in terms of TIRADS classification and dichotomous outcomes and relative to radiologist-based assessments. Clinicians should know about the strengths and weaknesses associated with the diagnosis of thyroid cancer using computer-aided diagnostic systems.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Han M, Ha EJ, Park JH, et al. Computer-Aided Diagnostic System for Thyroid Nodules on Ultrasonography: Diagnostic Performance Based on the Thyroid Imaging Reporting and Data System Classification and Dichotomous Outcomes. AJNR Am J Neuroradiol. 2020. PMID: 33361374. doi:10.3174/ajnr.A6922

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。