一项探索性多阅片者多病例研究:比较透射超声与乳腺X线摄影对乳腺癌病灶的召回率与检出率

An Exploratory Multi-reader, Multi-case Study Comparing Transmission Ultrasound to Mammography on Recall Rates and Detection Rates for Breast Cancer Lesions.
PubMed 文献 · Acad Radiol · 2020-12-03

该多阅片者多病例研究基于两项临床试验的回顾性数据,比较22名放射科医生使用三维定量透射超声与全视野数字乳腺X线摄影对108例乳腺病例的检出率和召回率。结果显示透射超声使非癌召回率显著降低16%、癌召回率降低2%、任何类型病灶检出率提高4%,合并召回率的置信评分AUC显著提高10%。作者认为透射超声改善非癌召回率而不实质性影响癌召回率,但病例数少需更大前瞻性研究。

要点

  • 透射超声较乳腺X线摄影非癌召回率降低16%(P=0.03),癌召回率降低2%(P>0.05)。
  • 透射超声任何类型病灶检出率较乳腺X线摄影提高4%(P>0.05)。
  • 合并癌与非癌召回率的置信评分AUC透射超声较乳腺X线摄影提高10%(P=0.01)。

核心结论

  • 该多阅片者多病例研究提示透射超声改善非癌召回率而不实质性影响癌召回率。
  • 主要局限性为回顾性数据病例数少,需更大前瞻性多阅片者多病例研究进一步评估。

研究设计与样本

  • 研究类型为多阅片者多病例(MRMC)研究,分析五项站点两项临床试验的回顾性数据。
  • 所有受试者在90天内接受全视野数字乳腺X线摄影(FFDM)和定量透射(QT)超声扫描。
  • 阅片研究采用全因子设计,纳入22名放射科医生和108例乳腺病例(42例正常、39例病理确诊良性、27例病理确诊癌症)。
  • 主要结果采用随机阅片者随机病例分析并校正位置偏倚,在预设的随机阅片者固定病例分析之后进行。

诊断标准与关键数值

  • 任何类型病灶平均检出率:QT超声较FFDM提高4%(P>0.05)。
  • 平均非癌召回率:QT超声较FFDM降低16%(P=0.03)。
  • 平均癌召回率:QT超声较FFDM降低2%(P>0.05)。
  • 合并癌与非癌召回率的置信评分平均AUC:QT超声较FFDM提高10%(P=0.01)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 主要局限性为回顾性数据病例数少。
  • 需要更大前瞻性多阅片者多病例研究进一步评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Three-dimensional Quantitative Transmission (QT) ultrasound imaging is an emerging modality for improving the detection and diagnosis of breast cancer. QT ultrasound has high resolution and high contrast to noise ratio, making it effective in evaluating breast tissue. This study compares radiologists' performance of noncancer recall rates and lesion detection rates using QT Ultrasound versus full-field digital mammography (FFDM) in a cross section of female subjects.

MATERIALS AND METHODS: In this multi-reader multi-case (MRMC) study, we examined retrospective data from two clinical trials conducted at five sites. All subjects received FFDM and QT scans within 90 days. Data were analyzed in a reader study with full factorial design involving 22 radiologists and 108 breast cases (42 normal, 39 pathology-confirmed benign, and 27 pathology-confirmed cancer cases). The main results used a random-reader random-case analysis adjusted for location bias performed after a primary predefined random-reader fixed-case analysis.

RESULTS: The readers' mean rate of detecting lesions of any type was 4% higher (p-value > 0.05) with QT imaging. The mean non-cancer recall rate improved significantly, showing a decrease of 16% with QT (p-value = 0.03), at the expense of a 2% decrease in the mean cancer recall rate (p-value >0.05) in comparison to FFDM. Combining performance on cancer and noncancer recall rates, the mean area under the receiver operator curve of confidence scores improved significantly by 10% with QT (p-value = 0.01).

CONCLUSION: This MRMC study indicates that QT improves non-cancer recall rates without substantially affecting cancer recall rates. The main limitation is the small number of cases from retrospective data. A larger prospective MRMC study is warranted for further assessment.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Malik B, Iuanow E, Klock J, et al. An Exploratory Multi-reader, Multi-case Study Comparing Transmission Ultrasound to Mammography on Recall Rates and Detection Rates for Breast Cancer Lesions. Acad Radiol. 2020. PMID: 33281042. doi:10.1016/j.acra.2020.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。