简化乳腺MRI与全诊断MRI在鉴别乳腺MRI检出病灶良恶性中的比较:多阅片者研究
本研究从111例新诊断乳腺癌患者的对侧乳腺MRI中回顾性构建仅含首帧增强图像的简化乳腺MRI方案,比较其与全诊断MRI在鉴别111个病灶(34个恶性、77个良性)良恶性中的表现。五位盲法阅片者独立评估,简化乳腺MRI敏感度低于全诊断MRI(58.8-82.4% vs. 79.4-100%),特异度高于全诊断MRI(39.0-74.0% vs. 19.5-45.5%,p ≤ 0.001),AUC相当(p > 0.05)。结论认为简化乳腺MRI总体表现与全诊断MRI相似,但敏感度较低、特异度较高,15%(5/34)的癌症被误分类。
要点
- 简化乳腺MRI仅用首帧增强图像,敏感度低于全诊断MRI(58.8-82.4% vs. 79.4-100%),特异度更高(39.0-74.0% vs. 19.5-45.5%,p ≤ 0.001)。
- 简化乳腺MRI的AUC与全诊断MRI相当(所有阅片者p > 0.05)。
- 15%(5/34)的癌症在简化乳腺MRI上为假阴性,延迟期更可疑的边缘或内部强化与两方案差异相关。
核心结论
- 简化乳腺MRI鉴别良恶性病灶的总体表现与全诊断MRI相似。
- 简化乳腺MRI敏感度低于全诊断MRI、特异度高于全诊断MRI,15%(5/34)的癌症被误分类。
研究设计与样本
- 回顾性研究,从全诊断MRI队列中获取仅含首帧增强图像的简化乳腺MRI方案图像。
- 样本为111例新诊断乳腺癌女性的111个对侧乳腺MRI检出病灶(34个恶性、77个良性),平均年龄49.8 ± 9.8岁(范围28-75岁)。
- 五位盲法阅片者独立使用乳腺影像报告和数据系统评估恶性可能性,行McNemar检验和受试者工作特征曲线下面积(AUC)分析。
- 分析两方案差异病灶的影像和病理特征。
关键影像表现/征象
- 延迟期图像上更可疑的边缘或内部强化与两方案间的差异病灶相关。
诊断标准与关键数值
- 简化乳腺MRI病灶表征敏感度为58.8-82.4%,全诊断MRI为79.4-100%,仅两位阅片者差异有统计学意义(p < 0.05)。
- 简化乳腺MRI病灶表征特异度为39.0-74.0%,全诊断MRI为19.5-45.5%,80%的阅片者简化乳腺MRI特异度更高(p ≤ 0.001)。
- 简化乳腺MRI的AUC与全诊断MRI相当(所有阅片者p > 0.05)。
临床应用与阅片要点
- 简化乳腺MRI方案仅采用首帧增强图像,阅片时需注意其敏感度可能低于全诊断MRI,15%(5/34)的癌症在简化乳腺MRI上为假阴性。
- 延迟期图像上更可疑的边缘或内部强化与两方案差异病灶相关,提示简化乳腺MRI判读时可关注这些特征。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the performance of simulated abbreviated breast MRI (AB-MRI) and full diagnostic (FD)-MRI in distinguishing between benign and malignant lesions detected by MRI and investigate the features of discrepant lesions of the two protocols.
MATERIALS AND METHODS: An AB-MRI set with single first postcontrast images was retrospectively obtained from an FD-MRI cohort of 111 lesions (34 malignant, 77 benign) detected by contralateral breast MRI in 111 women (mean age, 49.8. ± 9.8; range, 28-75 years) with recently diagnosed breast cancer. Five blinded readers independently classified the likelihood of malignancy using Breast Imaging Reporting and Data System assessments. McNemar tests and area under the receiver operating characteristic curve (AUC) analyses were performed. The imaging and pathologic features of the discrepant lesions of the two protocols were analyzed.
RESULTS: The sensitivity of AB-MRI for lesion characterization tended to be lower than that of FD-MRI for all readers (58.8-82.4% vs. 79.4-100%), although the findings of only two readers were significantly different (p < 0.05). The specificity of AB-MRI for lesion characterization was higher than that of FD-MRI for 80% of readers (39.0-74.0% vs. 19.5-45.5%, p ≤ 0.001). The AUC of AB-MRI was comparable to that of FD-MRI for all readers (p > 0.05). Fifteen percent (5/34) of the cancers were false-negatives on AB-MRI. More suspicious margins or internal enhancement on the delayed phase images were related to the discrepancies.
CONCLUSION: The overall performance of AB-MRI was similar to that of FD-MRI in distinguishing between benign and malignant lesions. AB-MRI showed lower sensitivity and higher specificity than FD-MRI, as 15% of the cancers were misclassified compared to FD-MRI.
引用
- Kim ES, Cho N, Kim SY, et al. Comparison of Abbreviated MRI and Full Diagnostic MRI in Distinguishing between Benign and Malignant Lesions Detected by Breast MRI: A Multireader Study. Korean J Radiol. 2020. PMID: 33289355. doi:10.3348/kjr.2020.0311
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。