非球形聚乙烯醇颗粒与三丙烯酰明胶微球对比:子宫动脉栓塞治疗症状性肌瘤后疼痛的随机对照试验
该随机临床试验将54例子宫肌瘤患者分为非球形聚乙烯醇(PVA)组与三丙烯酰明胶微球(TAGM)组,比较子宫动脉栓塞后疼痛。两组疼痛评分及芬太尼用量无差异,但PVA组补救镇痛药使用率更高、炎症反应更明显、短暂性全子宫缺血更常见。
要点
- PVA组补救镇痛药使用率33%高于TAGM组11%(P=0.049)。
- PVA组中性粒细胞与淋巴细胞比值变化幅度大于TAGM组(P=0.02)。
- PVA组短暂性正常肌层全子宫缺血发生率44%高于TAGM组15%(P=0.04)。
核心结论
- 子宫动脉栓塞中使用PVA颗粒与TAGM的疼痛评分和芬太尼剂量相似。
- PVA导致更强的炎症反应、更高的补救镇痛药使用率和更频繁的短暂性全子宫缺血。
研究设计与样本
- 随机临床试验,共评估54例参与者(平均年龄44岁±4岁),每组27例。
- 参与者分别接受非球形PVA颗粒(355-550 μm)或TAGM(500-700 μm)。
- 两组在栓塞后24小时内均使用芬太尼为基础的静脉患者自控镇痛及补救镇痛药。
- 测量中性粒细胞与淋巴细胞比值评估炎症反应;栓塞后1天行增强MRI评估优势肌瘤坏死及正常肌层缺血。
- 栓塞前及栓塞后3个月评估症状严重度评分与健康相关生活质量评分。
关键影像表现/征象
- 两组优势肌瘤完全坏死率无差异。
- PVA组短暂性正常肌层全子宫缺血发生率44%高于TAGM组15%(P=0.04)。
诊断标准与关键数值
- 疼痛评分及芬太尼剂量在最初24小时内两组无差异。
- 补救镇痛药使用率PVA组33% vs TAGM组11%(P=0.049)。
- 中性粒细胞与淋巴细胞比值变化:PVA组3.9(四分位距2.7-6.8) vs TAGM组2.5(四分位距1.5-4.6),P=0.02。
- 症状严重度评分:PVA组16(四分位距6-22) vs TAGM组19(四分位距9-34),P=0.45。
- 健康相关生活质量评分:PVA组93(四分位距80-97) vs TAGM组89(四分位距84-96),P=0.41。
临床应用与阅片要点
- 栓塞后1天增强MRI可用于评估优势肌瘤坏死及正常肌层缺血。
- PVA组短暂性全子宫缺血发生率更高,阅片时需注意正常肌层缺血表现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Data are limited regarding comparison between nonspherical polyvinyl alcohol (PVA) particles and tris-acryl gelatin microspheres (TAGM) in uterine artery embolization (UAE). Purpose To compare pain after UAE with PVA versus TAGM for treatment of symptomatic fibroids. Materials and Methods In this randomized clinical trial, participants were assigned to be administered nonspherical PVA (355-550 μm) or TAGM (500-700 μm). Both groups were administered fentanyl-based intravenous patient-controlled analgesia during the first 24 hours after UAE and rescue analgesics. Neutrophil-to-lymphocyte ratio was measured to assess inflammatory response. Contrast-enhanced MRI 1 day after UAE was used to evaluate dominant fibroid necrosis and ischemia of normal myometrium. Symptom severity score and health-related quality-of-life score were assessed before and 3 months after UAE. Variables measured over time were analyzed by using the generalized estimating equation method. Results A total of 54 participants (mean age, 44 years ± 4 [standard deviation]) were evaluated (27 participants in each group). Although pain scores and fentanyl dose were not different during the first 24 hours, use of rescue analgesics was higher in the PVA group (33% vs 11%; P = .049). After embolization, symptom severity score and health-related quality-of-life score were not different between groups (symptom severity score: 16 [interquartile range, 6-22] for PVA vs 19 [interquartile range, 9-34] for TAGM, P = .45; health-related quality-of-life score: 93 [interquartile range, 80-97] for PVA vs 89 [interquartile range, 84-96] for TAGM, P = .41). Changes in neutrophil-to-lymphocyte ratio from before to 24 hours after UAE were greater in the PVA group (3.9 [interquartile range, 2.7-6.8] for PVA and 2.5 [interquartile range, 1.5-4.6] for TAGM; P = .02). Rates of complete dominant fibroid necrosis were not different between groups, but transient global uterine ischemia of normal myometrium was more frequent in the PVA group (44% vs 15%; P = .04). Conclusion When used in uterine artery embolization, polyvinyl alcohol particles and tris-acryl gelatin microspheres resulted in similar pain scores and fentanyl dose. Polyvinyl alcohol resulted in a greater inflammatory response, higher rates of rescue analgesic use, and more frequent transient global uterine ischemia. © RSNA, 2020 See also the editorial by Spies and Frenk in this issue.
引用
- Han K, Kim SY, Kim HJ, et al. Nonspherical Polyvinyl Alcohol Particles versus Tris-Acryl Microspheres: Randomized Controlled Trial Comparing Pain after Uterine Artery Embolization for Symptomatic Fibroids. Radiology. 2020. PMID: 33350893. doi:10.1148/radiol.2020201895
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。