产前超声测量的边缘性胎盘脐带插入未发现可预测不良围产结局
本研究为单中心回顾性队列研究,纳入2014年9月至2016年8月间675例异常脐带插入孕妇中的183例符合标准者,在20周常规解剖超声诊断边缘性脐带插入。结果显示边缘性脐带插入与胎儿对分娩不耐受无统计学显著关联(OR 1.24,95%CI 0.55-2.80,P=0.71),且脐带插入点至胎盘边缘距离与围产结局无显著相关。作者认为边缘性脐带插入妊娠无论具体距离如何可能均不增加不良围产结局风险,对加强产前监测的必要性提出疑问。
要点
- 边缘性脐带插入与胎儿对分娩不耐受无统计学显著关联(OR 1.24,95%CI 0.55-2.80,P=0.71)。
- 超声测量的脐带插入点至胎盘边缘距离与围产结局无显著相关。
- 作者认为边缘性脐带插入妊娠可能不增加不良围产结局风险,对加强产前监测的必要性提出疑问。
关键影像表现/征象
- 边缘性脐带插入在20周妊娠常规解剖超声扫描中诊断。
- 脐带插入点至胎盘边缘距离通过超声复核确定。
诊断标准与关键数值
- 边缘性脐带插入与胎儿对分娩不耐受无统计学显著关联(OR 1.24,95%CI 0.55-2.80,P=0.71)。
- 边缘性脐带插入与次要结局无统计学显著关联。
- 脐带插入点至胎盘边缘距离与围产结局无显著相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The clinical importance of marginal cord insertion (MCI) is currently controversial. In this study, we examined the association between MCI and adverse perinatal outcomes. We also evaluated the ultrasound-measured distance from the site of placental cord insertion (PCI) to the placental margin (PCI distance) and perinatal outcomes.
METHODS: This was a retrospective cohort study of MCI and control pregnancies presenting to a single institution between September 2014 and August 2016. Marginal cord insertion was diagnosed on routine anatomy ultrasound scans at 20 weeks' gestation. The primary outcome was fetal intolerance to labor. Secondary outcomes of interest included mode of delivery, gestational age at delivery, Apgar scores at 1 and 5 minutes, birth weight, delivery complications, and neonatal intensive care unit admission. The PCI distance was determined by an ultrasound review. Statistical significance was evaluated by a χ2 analysis, descriptive statistics, Wilcoxon tests, and regression models with log-transformed outcomes, the PCI distance, or both as needed.
RESULTS: Of 675 abnormal cord insertion cases, we identified 183 that met inclusion criteria. We found no statistically significant association between MCI and fetal intolerance to labor (odds ratio, 1.24 [95% confidence interval, 0.55-2.80]; P = .71) or secondary outcomes. Furthermore, we found no significant correlation between perinatal outcomes and the PCI distance.
CONCLUSIONS: Our study suggests that MCI pregnancies, regardless of the specific PCI distance, might not be at increased risk of adverse perinatal outcomes. This finding questions the need for heightened antepartum surveillance of this patient population.
引用
- Lutz AB, Young-Lin N, Leon-Martinez D, et al. Measurement of Marginal Placental Cord Insertion by Prenatal Ultrasound Was Found Not to Be Predictive of Adverse Perinatal Outcomes. J Ultrasound Med. 2020. PMID: 33277931. doi:10.1002/jum.15586
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。