弥散张量成像用于鉴别子宫肉瘤与退变性子宫肌瘤
回顾性分析14例子宫肉瘤与30例退变性子宫肌瘤,比较DWI的ADC值、DTI的ADC值(ADCT)及FA值的诊断效能。子宫肉瘤三项参数均显著低于退变性子宫肌瘤,ADCT值诊断效能最高,AUC为0.974。
要点
- 子宫肉瘤的ADC、ADCT及FA值均显著低于退变性子宫肌瘤(均p<0.001)。
- ADCT值诊断效能最高,AUC 0.974,阈值≤1.322×10-9mm2/s时敏感度96.7%、特异度92.9%。
- DTI定量参数可用于鉴别子宫肉瘤与退变性子宫肌瘤,ADCT值最优。
核心结论
- DTI定量参数可用于鉴别子宫肉瘤与退变性子宫肌瘤,其中ADCT值诊断效能最高。
研究设计与样本
- 回顾性分析14例子宫肉瘤和30例退变性子宫肌瘤,由两名观察者使用ADW4.6工作站Functool软件分析DWI和DTI图像,在ADC图、ADCT图及FA图上各选取3个感兴趣区获取参数值,以ROC曲线比较诊断价值。
诊断标准与关键数值
- 子宫肉瘤诊断阈值:ADC≤1.290×10-3mm2/s(敏感度78.6%、特异度90%、AUC 0.875);ADCT≤1.322×10-9mm2/s(敏感度96.7%、特异度92.9%、AUC 0.974);FA≤0.192(敏感度86.7%、特异度85.7%、AUC 0.831)。
临床应用与阅片要点
- 阅片时可测量病灶ADC、ADCT及FA值辅助鉴别子宫肉瘤与退变性子宫肌瘤,ADCT值诊断效能最高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To explore the applicability of diffusion-tensor imaging (DTI) sequence quantitative parameters in differentiating uterine sarcoma (USr) from degenerative uterine fibroids (DUF).
MATERIALS AND METHODS: Fourteen cases of USr and 30 cases of DUF were analysed retrospectively. The diffusion-weighted imaging (DWI) and DTI images were analysed by two observers using Functool software on a ADW4.6 workstation. The images were post-processed to generate an apparent diffusion coefficient (ADC) map of DWI, ADC map of DTI (ADCT map), and fractional anisotropy (FA) map. Three regions of interest (ROI) were selected from the ADC, ADCT, and FA maps to obtain the ADC, ADCT, and FA values. The receiver operating characteristic (ROC) curves of all parameters were used to analyse and compare the diagnostic value of USr and DUF.
RESULTS: The ADC value, ADCT value, and FA value of USr (1.190 ± 0.262 × 10-3mm2/s, 1.165 ± 0.270 × 10-9mm2/s, 0.168 ± 0.063) were significantly lower compared to the values for DUF (1.525 ± 0.314 × 10-3mm2/s, 1.650 ± 0.332 × 10-9mm2/s, 0.254 ± 0.111; all p<0.001). The diagnostic threshold values for USr were: ADC ≤1.290 × 10-3mm2/s, ADCT ≤1.322 × 10-9mm2/s and FA ≤0.192. The corresponding sensitivities and specificities were 78.6%/90%, 96.7%/92.9%, and 86.7%/85.7%, respectively. The areas under the curve (AUC) were 0.875, 0.974, and 0.831, respectively.
CONCLUSIONS: DTI quantitative parameters can be used to differentiate USr from DUF. The ADCT value had the highest diagnostic efficacy.
引用
- Tian S, Niu M, Xie L, et al. Diffusion-tensor imaging for differentiating uterine sarcoma from degenerative uterine fibroids. Clin Radiol. 2020. PMID: 33358441. doi:10.1016/j.crad.2020.11.115
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。